Additional Parts Required; Location Requirements - Haier HLTD600AEW Manual Para El Usuario

Secadoras de ropa a gas y eléctricas
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ADDITIONAL PARTS REQUIRED

4" (10.2 cm) Rigid or Flexible Metal Exhaust Ducting
Vent Clamps
Duct Tape
Power Cord (US Electric Dryer Only)
-
A power supply cord kit must be purchased to meet local electrical codes.
The dryer must use a 3 or 4-wire NEMA 14-30 or 10-30 type SRDT or ST
(as required) power supply cord rated at 120/240 volt AC minimum,
30 amp, with 10 AWG conductors terminated with upturned ends or closed
loop connectors and marked for use with clothes dryers.
-
UL Listed Strain Relief
Gas Hookup Parts (Gas Dryer Only)
-
⅜" NPT Elbow
-
⅜" NPT Flare Adapter Fitting
-
⅜" Flexible Gas Connector
-
Pipe-Joint Compound
Mobile Home Installation Kit (Gas Dryer for Mobile Home Only)

LOCATION REQUIREMENTS

Do not install the dryer where gasoline or other ammables are kept or
stored. If the dryer is installed in a garage, it must be a minimum of
18 inches (45.7 cm) above the oor. Failure to do so can result in death,
explosion, re or burns.
The dryer must be installed on a solid floor. A concrete floor is the best.
The floor should be level with maximum slope of 1" (2.5 cm) under entire dryer.
A suitable location is protected from direct sunlight and heat sources such as
radiators, baseboard heaters, or cooking appliances.
Do not install on carpeting.
The location must have the appropriate electrical and gas supply outlets. See
"Electrical & Gas Supply Requirements" section for details.
Do not install the dryer in an area where the dryer will come into contact with
curtains, thick carpet, or anything that might obstruct the flow of combustion
and ventilation air.
Do not install or store this appliance where it will be exposed to water and/or to
the weather.
8
WARNING

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Hltd600acwHltd600agw

Tabla de contenido