Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62
5

PROGRAMMING

IMPORTANT! - After making all the connections, power the control unit and set the eight dip-switches on the board, on the basis
of the type of devices connected and the functions to be activated or deactivated. Refer to Table D for programming the unit.
Table D - Setting the dip-switches
Dip-switch
Setting
(1) OFF; (2) OFF
Switches
(1) OFF; (2) ON
1 - 2
(1) ON; (2) OFF
(1) ON; (2) ON
OFF
Switch 3
ON
OFF
Switch 4
ON
OFF
Switch 5
ON
OFF
Switch 6
ON
OFF
Switch 7
ON
OFF
Switch 8
ON
Description of the set function
Enables the Stop input for the connection of a 8.2 kΩ fixed resistor, without button "S" that excludes the inversion
(see Fig. 4)
Enables the Stop input for the connection of a 8.2 kΩ fixed resistor, with button "S" that intervenes at 30/40 mm from
the limit switch to exclude inversion (see Fig. 4)
Enables the Stop input for the connection of a NO (normally open) contact
Enables the Stop input for the connection of a NC (normally closed) contact
Enables the Stop input to stop the current manoeuvre and perform a brief inversion of the movement
Enables the Stop input to stop the current manoeuvre
Enables the Photo input for the connection of photocells
Enables the Photo input for being used as a closing command
Enables the following cyclical commands, of the step-by-step type: > Open > Stop > Close > Stop > (again...)
Enables the following cyclical commands, of the step-by-step type: > Open > Stop > (again...)
Disables the condominium function
Enables the condominium function
Enables the "Door open indicator light" function
Enables the Photo Test function
Disables the "Pause Time" for the automatic re-closing of the door, following an opening command
Enables the "Pause Time" for the automatic re-closing of the door, following an opening command
English – 10

Publicidad

Tabla de contenido
loading

Tabla de contenido