5.2.5 Electrical connections (Fig. 1)
•
Before you connect the equipment to the
power supply make sure that the data on the
rating plate are identical to the supply voltage.
•
If you use any extension cables, make sure
that they are suitable for outdoor use and
have large enough wires:
1 – 10 m: 1.5 mm²
10-30m: 2.5 mm²
•
Insert the power plug (8) on the power cable
(6) into the socket outlet.
6. Operation
The equipment consists of an assembly with a
pump, which is encased in a shock absorbing
housing. For an optimal working position the
equipment comes with a lance and a non-slip
gun, whose shape and confi guration comply with
the applicable regulations.
6.1 Using for the fi rst time
Once you have completely assembled the pres-
sure cleaner and made all the connections, pro-
ceed as follows:
Open the water inlet. Press safety pin „a" (Fig. 2)
on the spray gun and pull back trigger lever „b"
(Fig. 2) in order to bleed the trapped air out of the
equipment.
Turn on the equipment by switching the On/Off
switch (Fig. 1/3) to "ON".
To turn off , release the trigger lever (b). The
equipment will then go into standby. As soon as
you press the trigger lever (b) again, the pressure
cleaner will restart.
To turn off the pressure cleaner completely, set
the On/Off switch (Fig. 1/3) to "OFF".
6.2 Using detergent
•
Fill the detergent tank (10) with a suitable
cleaning agent.
•
The detergent will be added automatically in
low-pressure mode.
•
Detergent may be used only together with the
following accessories.
Anl_SA_TC_HP_1435_SPK8.indb 28
Anl_SA_TC_HP_1435_SPK8.indb 28
GB
6.2.1 Using detergent with the solid cone /
fl at fan lance
Set the solid cone / fl at fan lance (Fig. 10) to low-
pressure mode (n).
6.3 Holder for the gun/accessories (Fig. 7)
To save space when not in use, the gun and ac-
cessories can be kept in the holder provided.
Caution! Before using the pressure cleaner,
make sure that the high-pressure hose is comple-
tely unwound.
7. Replacing the power cable
If the power cable for this equipment is damaged,
it must be replaced by the manufacturer or its
after-sales service or similarly trained personnel
to avoid danger.
8. Cleaning and maintenance
Always pull out the mains power plug before star-
ting any cleaning work.
8.1 Cleaning
•
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it with compressed air at low
pressure.
•
We recommend that you clean the device
immediately each time you have finished
using it.
•
Clean the equipment regularly with a moist
cloth and some soft soap. Do not use
cleaning agents or solvents; these could
attack the plastic parts of the equipment. En-
sure that no water can seep into the device.
8.2 Maintenance
8.2.1 Testing the water intake fi lter
Periodically check the intake fi lter in order to pre-
vent clogging, which could jeopardize operation
of the pump.
To do this, unscrew the coupling for the water inlet
hose from the device and clean the exposed inlet
sieve under running water.
- 28 -
17.10.2017 08:05:26
17.10.2017 08:05:26