Before Starting The Equipment - EINHELL TC-HP 1435 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Keep the noise emissions and vibrations to a
minimum.
Only use appliances which are in perfect wor-
king order.
Service and clean the appliance regularly.
Adapt your working style to suit the appliance.
Do not overload the appliance.
Have the appliance serviced whenever ne-
cessary.
Switch the appliance off when it is not in use.
Wear protective gloves.
Residual risks
Even if you use this electric power tool in
accordance with instructions, certain resi-
dual risks cannot be rules out. The following
hazards may arise in connection with the
equipment's construction and layout:
1. Lung damage if no suitable protective dust
mask is used.
2. Damage to hearing if no suitable ear protec-
tion is used.
3. Health damage caused by hand-arm vib-
rations if the equipment is used over a pro-
longed period or is not properly guided and
maintained.

5. Before starting the equipment

5.1 Using the equipment correctly
The pressure cleaner must be stood on a le-
vel, stable surface.
It is recommended that you adopt the correct
operating position every time you use the
equipment, with one hand on the gun and the
other on the lance.
Never direct the water jet at electrical lines or
the equipment itself.
So that the pump does not suffer any damage
when it is not in use, a small amount of leaka-
ge from the pump is normal.
Never use the machine in potentially explosi-
ve areas under any circumstances!
The operating temperature must be between
+5 and + 60°C.
Do not cover or modify the lance or the spray
nozzles in any way.
The pressure cleaner is designed to be used
with cold or lukewarm water (max. 40 °C); hig-
her temperatures can damage the pump.
Do not use water that is dirty, gritty or con-
tains any chemical products, as these could
impair operation and shorten the life of the
Anl_SA_TC_HP_1435_SPK8.indb 27
Anl_SA_TC_HP_1435_SPK8.indb 27
GB
equipment.
Caution: Risk of explosion
Do not spray fl ammable liquids.
Warning
Water that has passed through the non-return
valve is not drinkable.
Warning
If cleaning agent gets into contact with your skin
or into your eye, rinse immediately with lots of
clean water. Then consult a doctor or follow the
steps described on the safety data sheet or provi-
ded by the manufacturer of the cleaning agent.
5.2 Assembly
5.2.1 Assembling the equipment
Assemble the pressure cleaner as shown in Fi-
gure 2-6.
5.2.2 Water inlet connector (Fig. 1/4)
The connection for the water inlet (4) is equipped
with a connector for standard hose coupling sys-
tems. Plug the hose coupling on the supply hose
(min. Ø 1/2") to the water inlet connector (4).
A backfl ow preventer must be installed between
the drinking water and the pressure cleaner! Ask
your local plumber about this.
5.2.3 Connecting the high-pressure hose
(Fig. 1-3; 5-6)
Remove the transport brace as shown in Figure 5
from the high-pressure hose connector (9). Con-
nect the high-pressure hose (18) to the connector
on the pressure cleaner (9) and to the connector
on the spray gun (14).
5.2.4 Fitting the gun attachments
You can attach either the normal lance or the
lance with rotating nozzle (Fig. 2) before the pres-
sure cleaner is used.
Solid cone / fl at fan lance (16)
The shape of the water jet can be changed from
solid cone to fl at fan by turning the nozzle (Fig. 8).
Lance with rotating nozzle (17)
To remove particularly stubborn dirt, use the lance
with the rotating nozzle (17).