MODELS
Punto Vortice STANDARD MODEL
NORMAL/AUTOMATIC
This model is turned on by means of the control switch.
With the automatic version, the closure vanes open a few
seconds after the unit has been turned on.
Punto Vortice TIMER NORMAL/AUTOMATIC
This model's timer has been factory set at the minimum
3-minute setting. The timer can be reset between 3 and
20 minutes by adjusting the trimmer (see Fig. 13).
The unit turns on automatically a few seconds after the
light turns on and keeps on operating for the preset
period of time after the is light turns off.
Punto Vortice PIR NORMAL/AUTOMATIC
This model's electronic circuit has a sensor that turns the
unit on for a preset period of time (adjustable between 3
and 20 minutes) every time it detects a person within its
range of detection (see Fig. 16).
Punto Vortice Pull Cord NORMAL/AUTOMATIC
This model has a manually-operated pull-cord switch for
turning the unit on and off.
Punto Vortice T HCS NORMAL/AUTOMATIC
This model has a preset relative-humidity indicator that
S
T
NORMAL
A
N
D
A
R
AUTOMATIC
D
L
O
NORMAL
N
G
L
I
AUTOMATIC
F
E
This is the complete range of Punto Vortice. Not all the versions are available in all countries.
DIAMETER STANDARD MODEL
TIMER
∅ 090
∅ 100
∅ 120
∅ 150
∅ 100
∅ 120
∅ 150
DIAMETER
STANDARD MODEL
∅ 100
∅ 120
∅ 150
∅ 100
∅ 120
∅ 150
turns the unit on when the R.H. exceeds 65%.This model
also has a timer that can be set between 3 and 20
minutes by adjusting the trimmer (see Fig. 14).
The unit turns on automatically a few seconds after the
light turns on and keeps on operating for the preset
period of time after the light turns off.
Punto Vortice MHC NORMAL/AUTOMATIC
This model has an MHC microprocessor system for
controlling relative humidity. The unit is programed to turn
on when the room temperature is 20°C and the R.H.
exceeds 65%. The microprocessor provides continual
control of the room air by reading the room temperature
and R.H. and calculating the average temperature over a
period of 48 hours. This procedure permits the
microprocessor to automatically set the optimum stop
time.This model also has a timer that can be set between
3 and 20 minutes by adjusting the trimmer (see Fig. 15).
Punto Vortice 12 VOLT NORMAL/AUTOMATIC
ATTENTION: FEED PRODUCTS ONLY WITH VORTICE
12V POWER SUPPLY
Products are built in III class, it means that the electrical
security is based on alimentation with very low security
voltage. This security is guaranteed only if the products
are powered with VORTICE GA 12V - 12V T - 12V P -
12V MHC - 12V HCS
PIR
PULL CORD
TIMER
PIR
PULL CORD
T HCS
MHC
12 V
T HCS
MHC
11