delivering timed commands; the user can also choose whether to follow
the "Installation wizard" procedure to program the motor, thereby leaving
Oview-TT the task of proposing the settable functions and parameters to
the installer.
• "Menus" section. This section enables installation of the motor in total
freedom, without the guided procedure. In this section, the installer
selects the items to be programmed as required, accessing the relative
sub-menus to modify data and confirm any selections made.
For an overview of the items in the sections Options and Menus, see
graphs A and B; for a detailed description of the items in each section,
carefully read all paragraphs in this chapter 4.
4.1 - "OPTIONS" section
This section is made up of 6 function groups. To access these, press the key
(l) Options once to display the relative items. To access the sub-menus of
each item, scroll through the list using the keys p and q, select the item
required and confirm by pressing key n. Graph A shows a summary of the
items available in the section Options.
4.1.1 - Description of items in the section "Options"
• Commands – Enables activation of all commands available on the motor.
Example: Stop, Ascent, Descent, Partial Open 1, Partial Open 2, Partial Open
3, Partial Open 4, Partial Open 5, Partial Open 6.
• Installation wizard – Enables correct programming of the motor with all
relative functions, according to the type of application, via the guide on
Oview-TT. After selecting the type of application, the programmer proposes
the technical options for programming the limit positions, enabling adjust-
ment of the weather sensor intervention levels and lastly enables manage-
ment of transmitters to aid completion of installation.
• Copy/Paste – Enables the user to copy parameters of a motor to then
paste them onto another motor to be programmed with the same parame-
ters. This eliminates the needs to repeat the entire installation procedure on a
second motor. Warning – This function is only available for motors that are
the same model.
• Timed commands – Oview is equipped with an internal clock that enables
use of Oview-TT as a timed transmitter to automatically send commands to a
motor, on the set days and at set times as required. To use this function, the
following is required: a) programming of the required parameters (type of
command, day/s of the week and time of transmission); b) permanent con-
nection of Oview-TT to the motor; c) continuous power supply to Oview-TT.
3 – English
+
l OPTIONS
|
|__Commands
|__Installation wizard
|__Copy/Paste
|__Commands
|__Timed command activation
|__Oview settings
Warning – If Oview-TT no longer receives power due to a power failure, the
internal clock continues to operate correctly; however, if a command delivery
is programmed during the power failure, this will not be executed.
Example: the following setting activates the Descent manoeuvre at 22.00
every Tuesday and Thursday.
mo tu we th fr sa su
––
22: 00
• Timed command activation – Enables activation/deactivation of the
"Timed command" function.
• Oview settings – Enables entry of the following operating parameters for
Oview-TT (to display and modify individual items, select and access the
screen displayed):
– Name: enables the user to assign a personal name to Oview-TT for easy
identification in a network of devices.
– Date/Time: enables entry of the local date and time. Using the arrow keys
t and u (2 and 4 – fig. 1) move between the date and time fields, and use
keys p and q (3 and 5 – fig. 1) to modify the relative values.
– Display brightness: enables adjustment of the display brightness. The value
is settable between 0% (minimum) and 100% (maximum). Note – After 30
seconds of inactivity, the display brightness is reduced to the minimum set
value.
– Key brightness: enables adjustment of the key brightness. The value is set-
table between 0% (minimum) and 100% (maximum). Note – After 30 sec-
onds of inactivity, the key brightness is reduced to the minimum set value.
– Installer password: function accessible for skilled users of Oview-TT in a
"BusT4" network (read paragraph C in the second part of the manual).
– User password: function accessible for skilled users of Oview-TT in a
"BusT4" network (read paragraph C in the second part of the manual).
– Language: enables selection of the required language.
– Information: enables display of technical data of Oview-TT. The data in this
field are read-only.
Graph A
––
Descent
––
On

Publicidad

Tabla de contenido
loading

Tabla de contenido