Operating Instructions SATA Automatic Gun
Adjust the material flow
Attention!
Using the material flow control for dosing can cause wear in the nozzles.
→ In normal operation, open the material flow control to the full extent. →
Use the material feed pressure to adjust the material flow.
→ Only use the material flow control to adjust the material flow for very
small material flow rates.
Notice!
The grub screw
for fixing the unit.
• Adjust the material flow with the material feed pressure.
• For small material flow rates, fine adjustment of the material flow can
be achieved by regulating the material flow control
Adjust spray fan pattern
• Adjust the flat fan by regulating the flat fan control [1-5].
• Adjust the round fan by regulating the round fan control [1-12].
Painting
Notice!
When painting, only use as much material as is required for the specific
procedure.
When painting, maintain the necessary spray distance (see chapter 4).
After painting, store or dispose of the material correctly.
• Adjust the necessary spray distance (see chapter 4).
• Ensure there is sufficient spraying air feed and material supply.
• Use the control air to trigger the control pulse for painting.
Switch off the automatic gun
• Switch off the control air.
• If painting has finished or a longer painting pause is planned, discon-
nect the spraying air and the material supply and heed the instructions
for care and storage (see chapter 11).
is glued firmly in the material flow control and is used