The Purchaser may only take advantage of the warranty provided by the Supplier if it carefully
observes the provisions in this manual, in particular if:
it works within the limits of use of the cabinet
it always performs constant and diligent maintenance;
it authorises the use of machine operators and technicians trained for the purpose and of
proven ability and aptitude (see chap. 4-5-6)
24.1. Warranty conditions (Italy)
Unless with custom conventions, machines are only guaranteed if new from the factory for one
year from the date of shipment with the exception of electrical parts and of those connected
parts.
Within this period the components that, at the discretion of our technicians, are considered
defective will be replaced or repaired free of charge.
For any further details regarding the warranty conditions see the conditions of sale.
24.2. Warranty (Overseas)
For warranties with countries overseas, see the agreements taken out with the respective
dealers or area managers.
i
Failure to observe the instructions provided in this manual will void the warranty.
25. Spare parts
Only use original spare parts.
replace components before they are worn out in order to prevent damage to persons and property
perform the periodic maintenance checks required by the contract
26. Troubleshooting
Problem
The cabinet
stops or does
not start
The cabinet
does not
cool
sufficiently
the cabinet is
noisy
05060154 00 26/05/2014
Possible causes
electrical black-out
main switch off
unplugged
protections interventions
(fuses, thermal-magnetic/
differential switches)
electronic controller failure
the cabinet is defrosting
the air vents are blocked
the load is not evenly
distributed
the cabinet is close to air
currents or heat sources
the cabinet is not level
screws and bolts are not
correctly closed
the cabinet is not level
Colonia 3 - Mini Colonia
Possible solutions
verify the cause of the black-out
turn on the switch
re-insert the plug
with the power restored, check that all
the electrical devices on the premises
can restart without tripping the
overcurrent protections, otherwise
modify the system to differentiate the
start-up of the various devices
i
If the power supply is not restored
in a short space of time store the
goods in a cold room to maintain
the storage temperature.
wait until the end of defrosting
(approximately 30 min)
unblock the air vents
reload the goods in an orderly manner
(Fig. 17)
check the position of the cabinet in the
premises (cap.13.)
level the cabinet (cap.13.)
tighten the screws and bolts
level the cabinet (cap.13.)
English