Electrical Specifications - Facom 720.P30 Guía De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 26

ELECTRICAL SPECIFICATIONS

Effective Frequency Range:
Output Sensitivity:
System Accuracy: Current probe accuracy + OSCILLOSCOPE/
Current Probe Accuracy ( dc to 20kHz ): ± (1% of reading + 2mA)
(Note: Accuracy is specified for a period of one year after calibration and
at 23°C ± 5°C, with relative humidity < 70%.)
Maximum Resolution:
Minimum Measurement:
di/dt Tracking Capability:
Conductor Position Sensitivity:
Load Resistance:
Temperature Coefficient:
10
NU-720.P30_0617 OK.indd 10
MULTIMETER accuracy
dc to 20kHz (0.5dB)
100mV/A
1mA dc/ac
5mA dc/ac
> 20A/μs
± 1% relative to center reading
10kΩ (typical)
0.2 x (specified accuracy) / °C
(0°C to 18°C, or 28°C to 50°C)
03/07/2017 11:52:24

Publicidad

Tabla de contenido
loading

Tabla de contenido