Fault: Pump runs all the time.
1. Is the float positioned with the magnet uppermost?
2. Is the reservoir lid (sensor) located firmly onto the reservoir, with
the float located inside the reservoir, around the sensor column?
3. Is there sludge inside the reservoir, preventing float from resting
on the bottom? (This may occur if pump has been in operation for
some time without cleaning. Clean using an anti-bacterial wash.)
Please note:
After installation and during operation, if you
notice air in the pipe between the reservoir and the
pump, you have a siphoning problem (Fit an Anti
Siphoning Device following step 10 on page 12.)
The pump will only switch off when the float
is at the bottom of the reservoir.
TR
Hata : Pompa sürekli olarak çalışıyor.
Şamandıranın mıknatıslı yüzü üst tarafa bakıyor mu ?
1.
Rezervuar kapağı rezervuarın üstüne sıkıca oturmuş mu, rezervuardaki
2.
şamandıra kolona oturmuş mu ?
Rezervuarda şamandıranın aşağı inmesini engelleyecek çamur var mı ?
3.
(Bu durum pompanın bir süre çalışması sonucunda ortaya çıkabilir.
Anti-bakteriyal sıvı ile temizleyiniz)
Lütfen dikkat ediniz
Montajdan sonra ve işletme esnasında rezervuarla pompa arasındaki
boruda hava farkederseniz sifon problemi ile karşı karşıyasınız demektir.
(Anti-sifon cihazının montajı için yukarıda yer alan 9. maddeye bakınız.)
Pompa, sadece şamandıra rezervuarının tabanında duruyorken çalışmaz
konumdadır
16
4053_080113_silentplus_orange.indd 16
1_1
Fault: Pump stops and starts and makes a loud noise.
1. The water is siphoning through the pump. Fit an Anti
Siphoning Device following step 10 on page 12.
Fault: Pump runs but does not pump any water.
1. Are there any air-leaks in the pipe running to the pump?
2. Check that reservoir, filter and inlet tube
are free of sludge and debris.
Fault: Pump isn't operating at all.
1. Is power reaching the pump? Is it correctly
wired? Is the voltage correct?
2. Is the pump very hot? A thermal cut-out may
have been activated to protect pump. This will
automatically reset once pump has cooled down.
Have you got another question?
Please contact our technical expert Dr. Bob.
Email: dr.bob@aspenpumps.com
Phone: +44 (0)1323 848842
Hata : Pompa bir durup bir çalışıyor ve aşırı gürültü yapıyor.
Su sifon etkisi yaparak pompaya geri dönüyor. Sifon etkisini engellemek
1.
için 9. maddeye bakınız.
Hata : Pompa çalışıyor ama hiç su pompalamıyor.
Rezervuar ve pompa arasındaki boruda bir sızıntı var mı ?
1.
Rezervuar ve hortumların içerisinde çamur ve pislik kalıntıları var mı ?
2.
Hata :
Pompa hiç çalışmıyor.
Pompaya elektrik geliyor mu ? Bağlantı doğru bir şekilde yapıldı mı ?
1.
Gelen voltaj doğru mu ?
Pompa çok mu sıcak ? Termal devre kesici devreye girmiş olabilir;
2.
Bu da pompanın soğuyana kadar çalışmamasını sağlar.
08/01/2013 16:17