STEINEL XLED CAM 1 Manual De Instrucciones página 20

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
While unit and Wi­Fi router are con­
necting:
– Acoustic signal every second.
– Status LED flashes green in rapid
succession.
Smartphone or tablet are connected
with the unit:
– Signal stops sounding.
– Status LED slowly flashes green.
• Configure unit via the Steinel CAM
app.
6. Use
All functions are selected and used
via the Steinel CAM app.
Factory settings
– Time setting: 1 minute
– Twilight setting: daylight mode
– Night light: 40%
Time setting
The time (switch­off delay) can be set
to 1 minute, 3 minutes, 10 minutes or
15 minutes. Every movement detected
re­activates the light.
Twilight setting
The brightness response threshold
(twilight) can be infinitely varied from ap­
prox. 10 to 10000 lux (daylight operating
mode).
Night light
– Night light provides constant illumi­
nation that switches ON when the
level of ambient light falls below the
brightness response threshold. Night
light can be infinitely varied from a
light output of 10% to 40%.
– Light is switched to 100% output
when movement is identified in the
detection zone. The unit then switch­
es back to night light.
Inserting the memory card
• Undo retaining screw and remove
cover. (Fig. 6.1)
• Insert memory card. (Fig. 6.2)
• Fit cover and tighten retaining screw.
(Fig. 6.4)
Aiming camera (Fig. 6.5)
Aiming floodlight head (Fig. 6.6)
• Undo the grub screws to alter aim.
After altering aim, fix floodlight head
in place with grub screws. (Fig. 6.6)
Adjusting the detection zone
To rule out inadvertent triggering or tar­
get specific danger spots, the detection
zone can be limited with film shrouds.
The film shroud is stuck onto the sensor
unit.
– Limit the detection zone's max. reach
with the top film shroud. (Fig. 6.7)
– Limiting the horizontal detection zone
with film­shroud segments cut to
size. One segment covers about 45°.
(Fig. 6.8/6.9)
• For adjustment, select the test mode
in the Steinel CAM app.
Restoring factory settings
• Undo retaining screw and remove
cover. (Fig. 6.1)
• Using the key, hold the reset button
down for approx. 7 seconds until the
signal sounds. (Fig. 6.3)
While resetting:
– Status LED lights up red.
After resetting:
– Acoustic signal every 4 seconds.
– Status LED flashes red.
• Open Steinel CAM app.
• Clear camera in Steinel CAM app.
• Re­configure unit.
➜ "Configuring unit"
• Fit cover and tighten retaining screw.
(Fig. 6.4)
19

Publicidad

Tabla de contenido
loading

Tabla de contenido