Cleaning And Maintenance - STEINEL XLED CAM 1 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
Camera function
– The camera films a sequence when
the sensor is triggered.
– The filmed sequence is saved on the
memory card and can be retrieved at
any time.
– The recorded data is only saved on
the unit's memory card.
– A maximum of two smartphones or
tablets can be connected to the cam­
era at the same time.
– A QR code is generated on the
smartphone or tablet which can
be read by another smartphone or
tablet.
– Once the sensor has triggered, the
user receives a push notification via
the Steinel CAM app.
• Open Steinel CAM app.
• Use image display and intercom
system.
➜ Further information on the functions
and setting options in the Steinel
CAM app.
7. Cleaning and
Maintenance
Hazard from electrical power.
Contact between water and live parts
can result in electrical shock, burns or
death.
• Light must not be wet­cleaned.
Risk of damage to property!
Using the wrong detergent can damage
the light.
• Make sure detergent does not harm
the surface.
• Clean light with a soft cloth and mild
detergent.
8. Troubleshooting
Unit does not switch ON.
– Fuse not switched ON or faulty.
• Switch ON fuse.
• Change faulty fuse.
– Break in wiring.
• Check wiring with voltage tester.
– Short circuit in mains power supply
lead.
• Check connections.
– Mains switch OFF.
• Switch ON mains switch.
– Wrong twilight setting selected.
• Re­set brightness response
threshold
– Detection zone too small.
• Check detection zone.
– Light source faulty.
• The light source cannot be
changed. Completely replace unit.
Unit does not switch OFF.
– Continued movement within the
detection zone.
• Check detection zone.
• If necessary, limit detection zone.
– Night light selected.
• Select programme without night
light.
– Manual override function selected.
• Deactivate manual override
function.
Unit switches ON without any identifi-
able movement.
– Install light at a non­vibrating site.
• Securely mount enclosure.
– Movement occurring, but is not iden­
tified by the observer (e.g. movement
of a small object in immediate light
vicinity).
• Check detection zone.
20

Publicidad

Tabla de contenido
loading