ANOMALIES, CAUSES, REMEDIES
The Vehicle does not start
1
Intense sparks when connecting the
clamps to the vehicle battery.
2
The internal batteries are charged, the
starting voltage choice is right, but the
3
vehicle does not start.
The red light blinks (after 24h of
charge)
1
The green and orange lights blink turn
by turn while charging.
2
The orange light blinks for more than
3h and does not change to green.
3
No lights are on.
4
In 24V mode, the green and orange
charge indicators blink abnormally.
5
After having pressed the test key, no
light indicators are on.
1
2 leds blink intermittently.
2
16
ENERGY STATION
ANOMALIES
CAUSES
The internal batteries are discharged.
Several starting were attempted wit-
hout break.
Voltage error
Voltage error
Polarity reversal.
Vehicle problem (rectifier, starter, glow
plugs...)
The battery does not charge or its vol-
tage does not increase enough.
Charger thermal protection.
The battery is sulfated or highly
discharged.
The fuse melt : Problem with the
power supply
No batteries
Batteries polarities reversal
Problem with the power supply
To charge a 24V external battery, the
Energy Station needs its 2 internal
batteries to operate.
The machine is plugged on the mains
and the charging switch is on.
There is no battery.
The battery voltage is to low.
The test updates every 0.5 seconds.
The battery voltage is on the rocking
threshold.
REMEDIES
Check the internal batteries condition
by pressing the test keys. Charge if
necessary.
Wait for 3 minutes between 2 star-
ting attempts. A starting must not last
more than 7 seconds.
Check the starting voltage selected
matches the vehicle battery voltage.
Check the connections and that the
starting voltage matches the selected
voltage.
Connect the red cable to the (+) bat-
tery terminal and the black cable to
the (-) terminal.
Take contact with a professional.
Check the collars are well tightened
on the battery terminals. Clean the
terminals and restart the charge. If
the red light blinks again, the batteries
are damaged.
Wait for several minutes (5 to 10
minutes) to cool the machine. The
charge will automatically restart as
soon as the temperature will have de-
creased enough.
The charger detects the presence of a
sulfated or highly discharged battery.
It will attempt to restore it with a 24h
specific charge.
Replace the fuse : Check the power
supply.
The charger does not detect the bat-
tery or the battery is damaged beyond
repair (voltage >0,5V).
Connect the red cable to the (+) bat-
tery terminal and the black cable to
the (-) terminal
Check the power supply.
Place the missing internal batterie(s).
Switch off the machine. (charging
switch on 0) or disconnect the charger
from the mains 230V. Press again the
test key.
Check the internal battery connections
(fastening collars...)
In this mode, the charger is supplied
through the battery to test. If the bat-
tery voltage is to low (<6V), no led
will switch on.
While reading, take the most unfavo-
rable case.