1 System description
DoorCom IP In-Home
Siedle DoorCom IP links the Siedle
In-Home bus: Video with the IP
world. Door calls are transformed via
the DoorCom IP and transmitted via
the IP network (Intranet) to certain
PCs. The video image at the door
station is converted and transmitted
via the IP network.
The DoorCom IP Software Client
is used here as a virtual in-house
telephone for communication to the
door station.
The Software Client must be
installed on every PC in the network
which is intended to receive a door
call.
Switching and control commands
can be visualized and operated using
the Software Client.
Assignment of door calls to the
Software Clients takes place using
an IWA address (Interface Working
Address) which is entered in the
DoorCom IP with the aid of the con-
figuration software.
The door call can optionally also
be held over the telephone system
using a telephone, while the picture
is displayed by the Software Client
and all control functions such as
door release can also be initiated by
the software. For this, a DCA 740-01
must additionally be connected to
the DoorCom IP. The video camera
picture continues to appear in the
Software Client on the PC monitor.
2 Safety remarks
System conditions:
Electrical voltage
Mounting, installation and servicing
work on electrical devices may only
be performed by a suitably qualified
electrician. Failure to observe this
regulation could result in the risk of
serious damage to health or fatal
injury due to electric shocks.
• When working at the device,
observe the remarks relating to
mains cut-off.
• Observe the standard DIN
EN 60065!
When establishing the electronic
connection, observe the require-
ments of VDE 0805 /EN 60950.
• The building installation must
include an all-pole mains switch
with a contact separation of at least
3 mm.
• Ensure maximum fusing of 16 A
for the mains connection in the
building installation.
• When planning, the required
distributor space for switch panel
mounted devices must be taken into
account.
• No external voltages >30 V AC/DC
may be applied to bus users.
Devices with 230 V connection
In accordance with DIN VDE 0100
part 410, section 411.1.3 attention
must be paid to ensuring a safe
separation between system lines and
the mains voltage; i.e. system and
mains cores must not be permitted
to touch! The system line cable
(extra-low safety voltage) must
be stripped back by the minimum
possible.
For mains connection and network
settings such as assignment of the IP
address, the responsible network
administrator must be consulted.
Find out about the necessary safety
measures and system requirements
before starting installation and com-
missioning of the DoorCom IP.
System conditions for the
bus programming software
BPS 650‑...
System requirements, software
conditions:
• IBM-compatible PC with CD-ROM
drive
• Intel Pentium III/1 GHz, and com-
patible CPUs
• Main memory with at least
512 MB RAM
• Powerful graphics card
• Operating systems from
Microsoft® Windows Vista/Windows
7/Windows 8
• Appr. 25 MB free space on the
hard disk (for BPS 650-... incl. help
file)
• Sufficient free storage space for
project data (appr. 5-250 kB per
project)
• Microsoft Internet Explorer 6.0 or
higher
• Acrobat Reader 7.0 or higher
• Where necessary up to 150 MB
free space on the hard disk for
additional service packs, Internet
Explorer, Acrobat Reader, etc.
• The PRI 602-... USB is required for
programming.
3