Troubleshooting - Emerson BUILDER Serie Manual Del Propietário

Ocultar thumbs Ver también para BUILDER Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
TROUBLESHOOTING YOUR FAN.
TROUBLE
1. Fan will not start.
1. Reversing switch in neutral position.
2. Fuse or circuit breaker blown.
3. Loose power line connections to the fan,
2. Fan sounds
1. Blades not attached to fan.
noisy.
2. Screws securing fan blade flanges to
3. Wire connectors inside switch housing
4. Screws holding flanges to blades are loose.
3. Fan wobbles
1. Setscrews in motor coupling is loose.
or shakes
excessively.
2. Setscrew in hanger ball/downrod
3. Screws securing fan blade flanges to
4. Fan blade flanges not seated properly.
5. Hanger bracket and/or ceiling outlet box
6. Fan blades out of balance.

10. Troubleshooting

!
PROBABLE CAUSE
or loose switch wire connections in
the switch housing.
motor are loose.
rattling.
assembly is loose.
motor are loose.
is not securely fastened.
WARNING
1. Make sure reversing switch position is all the
way to one side.
Make sure main power is turned OFF.
2. Check main and branch circuit fuses or circuit
breakers.
3. Check line wire connections to fan and switch
wire connections in switch housing.
1. Attach blades to fan before operating.
2. Check to make sure the screws which attach
the fan blade flanges to the motor are tight.
3. Check to make sure wire connectors in switch
housing are not rattling against each other or
against the interior wall of the switch housing.
4. Tighten screws securely.
Make sure main power is turned OFF.
1. Tighten the setscrews securely in the motor
coupling.
2. Tighten the setscrew in the hanger ball/downrod
assembly.
3. Check to be sure screws which attach the fan
blade flanges to the motor are tight.
4. Check to be sure the fan blade flanges seat firmly
and uniformly to the surface of the motor. If flanges
are seated incorrectly, loosen the flange screws
and retighten according to the procedure in the
section on to "Ceiling Fan Assembly".
5. Tighten the hanger bracket screws to the outlet
box, and/or secure outlet box.
6. Interchanging an adjacent (side-by-side) blade
pair can redistribute the weight and result in
smoother operation.
20
SUGGESTED REMEDY
WARNING
!
WARNING
!
U.L. Model No.: 52-ANT

Publicidad