Spraying
Observe the instructions in the section entitled "Safety".
Operate the device only while it is vertical or suspended upright and nearly vertical.
Avoid allowing drops of spray to drift onto areas that are not being treated.
Observe the instructions of the spray product manufacturer!
1. Suspend the device from your shoulder. (Fig. 13)
+
To prevent dripping, hold the spray wand up when first spraying and activate the
shut-off valve until no more liquid mixed with air is emerging from the nozzle.
2. If required, reset the lock [40] and activate the shut-off valve [9]. (Fig. 15)
► Spraying may now begin.
3. Make certain the optimum spraying pressure is set (→ Table 2) on the piston pressure
gauge [16].
Spraying rate
Spraying pressure
1.5 bar (21.8 psi)
2.0 bar (29.0 psi)
3.0 bar (43.5 psi)
Table 2. Dependence: Spraying rate – spraying pressure
4. If the spraying pressure decreases more than 0.5 bar (7.3 psi) from the optimum level,
pump some more.
+
If liquid mixed with air emerges from the nozzle, the tank is empty.

After Usage

Observe the instructions in the section entitled "Safety".
Never leave liquid in the device.
1. Pull up the red button on the safety valve [12] until all excess pressure is released from
the tank. (Fig. 4).
2. Lock the pump handle in place [13]. (Fig. 5).
3. Unscrew the pump [2] from the tank [1]. (Fig. 6).
Collect and dispose of the residual liquid and the tank according to all applicable
laws, requirements and regulations.
Follow the instructions of the spray product manufacturer!
4. Empty and rinse the device with clear water.
5. Wipe off the device with a moist cloth.
6. For drying and storing the device, keep the tank and pump separate in a dry place
protected from sunlight and freezing temperatures.
Clean the protective equipment and yourself every time after usage.
flat jet nozzle
80-01
0,29 l/min
0,32 l/min
0,39 l/min
17
hollow cone nozzle
80-02
0,56 l/min
0,64 l/min
0,78 l/min
ENGLISH
1,1 mm
0,48 l/min
0,56 l/min
0,69 l/min