• Restart the high pressure cleaner by turning the main switch (2) to position "1".
Note: during this restart phase, the high pressure cleaner will immediately stop operating after
the initial peak, as the Total Stop device will take effect.
• Use the cleaner gun's lever (26) to start operation of the high pressure cleaner and thus start
cleaning.
• You can alter the angle of the jet by adjusting the head (27) (Fig. 4 - Positions a and b).
5.4 u
D
se WIth
eterGents
m
WARNING
• The high pressure cleaner was designed to be used with the detergents recommended by the
Manufacturer. Use of other detergents or chemicals can affect the safety of the high pressure
cleaner.
Never suck up liquids, which contain solvents, petrol, diluents, acetone and fuel oil, as these
products are highly inflammable, explosive and toxic when nebulized.
• Carefully read the instructions and warnings on the label of the detergent to be used.
• Store detergents in a safe place out of children's reach.
• Should detergent come into contact with your eyes, wash immediately with water. Contact a
doctor without delay and remember to take the container of detergent with you.
• If detergent is swallowed, do not provoke vomiting. Contact a doctor without delay and re-
member to take the container of detergent with you.
The recommended detergents, are over 90% biodegradable.
For information on how to use the detergents, refer to the instructions on the label on the container
of detergent.
• Fill the bottle (21) with the desired detergent
• Regulate the detergent suction capacity in the following way:
- disconnect the rod (20) from the lance (19);
- the L tooth on the rod (20) must match with one of the numbers on the inside of the lance (19)
(1: minimum suction, 6: maximum suction);
- re-connect the rod (20) in the lance (19).
• Insert the bottle (21) in the foam lance (19).
• Put the main switch (2) to position "0" and connect up the lance (19) and the spray gun (14).
• Start up the high pressure again, by putting the main switch (2) to position "1" and operating its
lever (26) (suction and mixing will start automatically when water goes through).
5.5 I
u
nterruptInG
Release the lever (26) on the cleaner gun and the water cleaner will automatically stop.
The water cleaner starts operating normally again when the lever on the cleaner gun is pressed again.
m
WARNING
• It is important to remember that the high pressure cleaner is still operational when it is in Total
Stop mode. Therefore, always put the main switch (2) in position "0", remove the plug from
the power outlet, press the lever (26) on the cleaner gun to eliminate any remaining pressure
and lock the safety protection device (25) (Fig. 4 - position S), before leaving it unattended,
even for a short time.
- the water cleaner is not left unattended in the presence of unsupervised children, elderly
or disabled people.