Application Example - Würth BST 350 Traducción Del Manual De Instrucciones De Servicio Original

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51

Application example

Cartridge power
green/yellow
yellow
red
The cartridge strengths specified here are based on
experience and may differ dependent on the quality
of the substrate.
Substrate and separations
The cartridge power suitable for the substrate must
be determined by performing a trial fastening. Start
with the weakest cartridge (green). For substrates
with extremely high tensile strengths/densities,
please contact your Würth customer service agent.
Substrate
Suitable
Normal strength concrete
Sand-lime brick
Structural steel
Cast steel
Ductile cast iron
Light alloys
Minimum substrate thickness
Check the substrate thickness. The minimum penetra-
tion depth of the fastener and the minimum thickness
of the substrate must exist to ensure safe holding of
the fastening.
Substrate
Penetration
depth
Concrete /
> 20 mm
brickwork
Steel
8 -11 mm
22
Substrate
Sand-lime brick
Concrete C20/25-30/37
(B25-B40)
Steel S 235 J (St37)
Unsuitable
Glass
Ceramics
Hardened steel
Minimum
thickness
100 mm
6 mm
Minimum centre to centre and edge
distances of the substrate
At the penetration point the distance to free edges
must be sufficiently great that the sideways exiting of
the fastener is prevented.
The fasteners must be driven in sufficiently far apart
to prevent their coming out due to breaking or crack-
ing of the substrate material.
Brick-
work
Minimum
7.5 cm
centre-to-cen-
tre distance
Minimum
100 mm 100 mm
edge distance
Selection of fasteners
Only use the fasteners recommended by Würth for
this tool (see accessories). Due to the constant new
development of fastenings, it is possible that not
all fasteners are shown. Therefore please ask your
Würth customer service advisor or see the latest
catalogue.
Operation (Fig. II)
WARNING !
Injuries or material damage due to
unintentional triggering.
 Unintentional firing could be trig-
gered and cause severe injuries.
¾ Do not hold the trigger pressed
down, if the tool is not being used.
¾ Never point the tool towards
any part of your body, towards
yourself or towards other persons.
Functional check
Press the unloaded tool, without inserted
cartridges and fasteners against a suitable
fastening substrate.
Press trigger [4]
3 A clear "click" must be heard.
Release the contact pressure.
Concrete,
Steel
Steel reinforced
concrete
7.5 cm
20 mm
15 mm

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

0864 22

Tabla de contenido