Installation Instructions; Construction; Location; Electrical Connections - Hoshizaki FM-1000AKE Manual De Instrucciones

Ocultar thumbs Ver también para FM-1000AKE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 47
ENGLISH
I. INSTALLATION INSTRUCTIONS

1. CONSTRUCTION

2. LOCATION

This icemaker is not intended for outdoor use.
The icemaker should not be located next to ovens, grills or other high heat producing equipment.
This appliance is not suitable for installation in an area where a water jet could be used.
The location should provide a firm and level foundation for the icemaker.
Do not place anything on top of the icemaker or in front of the louver.
Normal operating ambient temperature should be within 5°C to 40°C. Normal operating water temperature should be within
5°C to 35°C. Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect
production capacity.
Allow the clearance specified below for proper air circulation and ease of maintenance and/or service should they be required.
Top View (except FM-600AKE)
Rear
15cm
Left
15cm
ICEMAKER
Front
In some high humidity environments, condensation may form inside the machine and drip onto the floor. Do not install where
the floor can be affected by water.

3. ELECTRICAL CONNECTIONS

This icemaker requires an earth that meets the national and local electrical code requirements.
Disconnect the main power supply before any maintenance, repairs or cleaning is undertaken.
Power Supply Cord
Top Panel
Front Panel
Air Filter
(Air-Cooled Model)
IMPORTANT
Top View (FM-600AKE only)
Right
Left
15cm
30cm
THIS APPLIANCE MUST BE EARTHED
Operation Panel
Louver
WARNING
CAUTION
NOTICE
Rear
15cm
Right
30cm
ICEMAKER
Front
WARNING
2
Side View
Top
60cm
Front
15cm
ICEMAKER
Rear

Publicidad

Tabla de contenido
loading

Tabla de contenido