Prerequisites for the
appliance's stability
Caution
Create stability for the appliance
prior to all work on or with the
appliance to prevent accidents
or damage.
The stability of the appliance is war-
ranted when it is placed onto an even
surface.

Operation

Description of the Appliance

1 Power cord with plug
2 Drum edge holder
3 Locking valve
4 O ring
5 Housing bowl for level switch
6 Housing cover for level switch
7 Hose coupling
8 Pressure hose
9 Hose clamp
10 Level sensor
11 Level switch attachment
12 Carrying handle
13 Hose connection G
for hose coupling
16
3
/
(24.4 mm)
4
EN
Preparing the drum pump
operation
Screw the hose connection on to
the pump
Connect the hose connection to the
hose coupling of the drum edge
holder.
Illustration
Screw the housing bowl and the O-
ring onto the drum edge holder.
Place the level switch into the hous-
ing bowl.
Press the housing cover down onto
the housing bowl until it locks.
Illustration
Slide the drum edge holder onto the
container edge until it is properly
seated.
Illustration
Place the pump on a stabil surface
in the liquid to be transported. Im-
merse it using a rope tied to the
handle or hang it into the container
by the hose.
The suction area should not be
blocked fully or partially through the
impurities.
Illustration
Close locking tap (arrow horizontal).
Different uses of the level
switch
Illustration
In automatic operation, set the re-
quired switching height by clamping
the level switch cable into the stop-
per.
Illustration
In manual operations mode, align
the level sensor upward (cable
pointing downward). Tip: Push the
cable of the level sensor like a loop
through the handle.
– 4