SIMPLIFIED INSTRUCTIONS FOR RAPID WITH PARK-CRX
Insert the bar with its hub vertically into the RAPID drive shaft. Attach with the screw (provided).
Insert the balancing springs (if not inserted at the factory).
Release the barrier to move the bar manually. To do so, use the RIB key provided and turn it
clockwise until the stop is reached.
Adjust the screws on the mechanical stops in such a way that when light pressure is applied
on the bar, the screws are gently pressed.
The electric limit switches are pre-configured at the factory.
Make the electrical connections (the motor and electrical safety devices are connected at
the factory).
The photocell and fence contacts are bridged at the factory. If you intend to use these,
remove the respective bridges beforehand.
STEP-BY-STEP
STOP
+
CLOSE
OPEN 1
LSC
LSO
LSSC
LSSO
LSC – Closing limit switch contact
LSO – Opening limit switch contact
LSSC – Closing slowing down limit switch contact
LSSO – Opening slowing down limit switch contact
+
+
BUZZER
LED
R=2K2
-
_
12 Vdc max 0.5A for ACCESSORIES
12 Vdc max 0.5A for CONTACT SELF-TEST
TIMER TO KEEP THE BARRIER
OPEN
ANTENNA – use an RG58 coaxial cable
ANTENNA SHEATHING
_
+
_
+
ENTRY
SENSITIVE EDGE
NC
NO
COM
S
D-
D
+
MAGNETIC SENSOR
EXIT
S
D-
D

Publicidad