Changing the set parameters of the charging curve with battery charger on board

The battery charger 1 is predisposed to charge the Lead-Acid or AGM batteries as show on the label near the power
cord connector (see picture page 18). The settings for the type of battery must be done using the switches
(dipswitch) 2 (see picture) and consult the "dipswitch setting tables for battery charger"- CBHD1 24V. - 13A USA
CEC. To access the dipswitches 2, remove the cap 3 on the battery charger 1.
!
Caution!
To prevent damage to the connected batteries, select the proper parameter (curve) associated with the bat-
tery type by following the instructions indicated in the table below and in the BATTERY CHARGER USER AND
MAINTENANCE MANUAL.
Dipswitches (2) setting tables for battery charger "CBHD1 24V. - 13A USA CEC"
(with nr. 2, 12V batteries)
In the following tables you can fi nd meaning of all diff erent position of dipswitch for programming CBHD1 24V. -
13A USA CEC battery charger.
DIP 1, DIP 2, DIP 3, DIP 4 for the selection of the CHARGING CURVE (example with selected curve 1 and/or 3).
Dip 1
Dip 2
Dip 3
> OFF
OFF
OFF
OFF
ON
OFF
> ON
OFF
OFF
ON
ON
OFF
1
Dip 4
Charging curve
ON
1 (curve for IUIa GEL EXIDE batteries)
ON
2 (curve for IUoU AGM batteries) Use with NSS #7696501 AGM battery
ON
3 (curve for IUIa Lead-Acid "Wet" batteries) Use with NSS #6393651 battery
ON
4 (curve for IUIUo AGM DISCOVER batteries )
19
SW1
SW2
ON
OFF
DP1 DP2 DP3 DP4
2
3
VB
Current
(Voltage)
13
24