Danfoss VLT AQUA Serie Instrucciones De Montaje página 160

Ocultar thumbs Ver también para VLT AQUA Serie:
Tabla de contenido

Publicidad

5 Programación del convertidor de frecuencia
5.3.23 Opción CTL cascada 27-**
Par.
Descripción de parámetro
Nº #
27-0* Control & Status
27-01
Pump Status
27-02
Manual Pump Control
27-03
Current Runtime Hours
27-04
Pump Total Lifetime Hours
27-1* Configuration
27-10
Cascade Controller
27-11
Number Of Drives
27-12
Number Of Pumps
27-14
Pump Capacity
27-16
Runtime Balancing
27-17
Motor Starters
27-18
Spin Time for Unused Pumps
5
27-19
Reset Current Runtime Hours
27-2* Bandwidth Settings
27-20
Normal Operating Range
27-21
Override Limit
27-22
Fixed Speed Only Operating Range
27-23
Staging Delay
27-24
Destaging Delay
27-25
Override Hold Time
27-27
Min Speed Destage Delay
27-3* Staging Speed
Velocidades de ajuste automático de cone-
27-30
xión por etapas
27-31
Stage On Speed [RPM]
27-32
Stage On Speed [Hz]
27-33
Stage Off Speed [RPM]
27-34
Stage Off Speed [Hz]
27-4* Staging Settings
27-40
Ajustes automáticos de conexión por etapas
27-41
Ramp Down Delay
27-42
Ramp Up Delay
27-43
Staging Threshold
27-44
Destaging Threshold
27-45
Staging Speed [RPM]
27-46
Staging Speed [Hz]
27-47
Destaging Speed [RPM]
27-48
Destaging Speed [Hz]
27-5* Alternate Settings
27-50
Automatic Alternation
27-51
Alternation Event
27-52
Alternation Time Interval
27-53
Alternation Timer Value
27-54
Alternation At Time of Day
27-55
Alternation Predefined Time
27-56
Alternate Capacity is <
27-58
Run Next Pump Delay
27-6* Entradas digitales
27-60
Entrada digital Terminal X66/1
27-61
Entrada digital Terminal X66/3
27-62
Entrada digital Terminal X66/5
27-63
Entrada digital Terminal X66/7
27-64
Entrada digital Terminal X66/9
27-65
Entrada digital Terminal X66/11
27-66
Entrada digital Terminal X66/13
27-7* Connections
27-70
Relay
27-9* Readouts
27-91
Cascade Reference
27-92
% Of Total Capacity
27-93
Cascade Option Status
27-94
Cascade System Status
160
Valor predeterminado
4-set-up
[0] Ready
All set-ups
[0] No Operation
2 set-ups
0 h
All set-ups
0 h
All set-ups
[0] Disabled
2 set-ups
1 N/A
2 set-ups
ExpressionLimit
2 set-ups
100 %
2 set-ups
[0] Balanced Priority 1
2 set-ups
[0] Direct Online
2 set-ups
ExpressionLimit
All set-ups
[0] No reiniciar
All set-ups
ExpressionLimit
All set-ups
100 %
All set-ups
ExpressionLimit
All set-ups
15 s
All set-ups
15 s
All set-ups
10 s
All set-ups
ExpressionLimit
All set-ups
[1] Activado
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
[0] Desactivado
All set-ups
10.0 s
All set-ups
2.0 s
All set-ups
ExpressionLimit
All set-ups
ExpressionLimit
All set-ups
0 RPM
All set-ups
0.0 Hz
All set-ups
0 RPM
All set-ups
0.0 Hz
All set-ups
[0] Desactivado
All set-ups
null
All set-ups
0 min
All set-ups
0 min
All set-ups
[0] Desactivado
All set-ups
ExpressionLimit
All set-ups
0 %
All set-ups
0.1 s
All set-ups
[0] Sin función
All set-ups
[0] Sin función
All set-ups
[0] Sin función
All set-ups
[0] Sin función
All set-ups
[0] Sin función
All set-ups
[0] Sin función
All set-ups
[0] Sin función
All set-ups
[0] Standard Relay
2 set-ups
0.0 %
All set-ups
0 %
All set-ups
[0] Disabled
All set-ups
0 N/A
All set-ups
®
MG.20.P3.05 - VLT
es una marca registrada de Danfoss
Manual de Funcionamiento para VLT AQUA
Cambio du-
Índice de
rante el fun-
conversión
cionamiento
TRUE
-
TRUE
-
TRUE
74
TRUE
74
FALSE
-
FALSE
0
FALSE
0
FALSE
0
TRUE
-
FALSE
-
TRUE
0
TRUE
-
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
0
TRUE
-
TRUE
67
TRUE
-1
TRUE
67
TRUE
-1
TRUE
-
TRUE
-1
TRUE
-1
TRUE
0
TRUE
0
TRUE
67
TRUE
-1
TRUE
67
TRUE
-1
FALSE
-
TRUE
-
TRUE
70
TRUE
70
TRUE
-
TimeOfDayWoDa-
TRUE
0
TRUE
0
TRUE
-1
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
TRUE
-
FALSE
-
TRUE
-1
TRUE
0
TRUE
-
TRUE
0
High Power
Tipo
Uint8
Uint8
Uint32
Uint32
Uint8
Uint8
Uint8
Uint16
Uint8
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Uint16
Uint16
Uint16
Uint16
Uint8
Uint16
Uint16
Uint16
Uint16
Uint8
Uint16
Uint16
Uint8
Uint8
Uint16
Uint16
Uint16
Uint16
Uint8
Uint8
Uint16
Uint16
Uint8
te
Uint8
Uint16
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Uint8
Int16
Uint16
Uint8
VisStr[25]

Publicidad

Tabla de contenido
loading

Tabla de contenido