Startup Wizard Parameter Description - Grundfos RSI Serie Instrucciones De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

5.2 Startup wizard parameter description

Name
Language Selection
Startup wizard
Motor type
Motor Nom Voltage
Motor Nom Freq
Motor Nom Speed
Motor Nom Current
Motor Cos Phi
Motor Nom Power
Output Sinus Filter
Pump Selection
Module MP Voltage
Modules in series
Application
The User settings column is left blank to allow users
to write down their own input settings.
After modifying the parameters in the table
above, the inverter needs to be stopped
and started again to update the parame-
ters.
No record is made of undervoltage fault
caused by insufficient power due to low
sunlight intensity.
Description
Select language
Select startup wizard
Select motor technology
Motor rated voltage
Motor rated frequency
Motor nominal speed
Motor rated current
Motor power factor
Motor rated power
Select if sine-wave filter is used or not
Grundfos pump family
Vmp maximum power point voltage
Number of solar panels in series
Select application Solar or PID with so-
lar
Factory setting
English
Yes
Induction motor
Variant-dependent
50
2850 RPM
Size-dependent
Size-dependent
Size-dependent
Yes
SP
33
18
Solar standard
Rotation direction:
1. Check the rotation direction at start up,
on a sunny day.
2. Start the pump and observe the water
flow.
3. Stop the pump. In the Main menu, go
to Quick setup, locate Rotation direc-
tion, and change it to reverse.
4. Start the pump and observe the water
flow.
5. Stop the pump. In the Quick setup
menu, select the direction that provides
the most water.
Minimum frequency for discharge:
1. Set the minimum frequency for the dis-
charge flow, on a sunny day.
2. On the keypad, press Position 7 and
select Set min. Frequency.
3. Start the pump and observe the water
flow.
4. If no flow is observed, increase the fre-
quency until the water is flowing.
5. Press OK to store the new minimum
frequency.
User setting
25

Publicidad

Tabla de contenido
loading

Tabla de contenido