Serial settings
(o
Device identification code
s. p
Serial interface protocol
ba
Baudrate selection
pt
Parity selection
In
Inputs setting
Type of probe, signal and
tP
scale of main input
tP
PROBE
without
TYPE
dec. point
Probe: TC
0
TC J °C
0/1000
1
TC J °F
32/1832
2
TC K °C
0/1300
3
TC K °F
32/2372
4
TC R °C
0/1750
5
TC R °F
32/3182
6
TC S °C
0/1750
7
TC S °F
32/3182
8
TC T °C
-200/400
9
TC T °F
-328/752
10
TC B °C
44/1800
11
TC B °F
111/3272
12
TC E °C
-100/750
13
TC E °F
-148/1382
14
TC N °C
0/1300
15
TC N °F
32/2372
16
TC LGOST °C
0/600
17
TC LGOST °F
32/1112
18
TC U °C
-200/400
19
TC U °F
-328/752
20
TC G °C
0/2300
21
TC G °F
32/4172
22
TC D °C
0/2300
23
TC D °F
32/4172
24
TC C °C
0/2300
25
TC C °F
32/4172
26
TC °C
Custom
27
TC °F
Custom
Probe: RTD
28
PT100 °C
-200/850
29
PT100 °F
-328/1562
30
JPT100 °C
-200/600
31
JPT100 °F
-328/1112
Probe: PTC - NTC
32
PTC °C
-55/120
33
PTC °F
-67/248
34
NTC °C
-10/70
35
NTC °F
14/158
0 ... 247
SP
Serial Protocol
0
CENCAL GEFRAN
1
MODBUS RTU
bA
Baudrate
0
1200
1
2400
2
4800
3
9600
4
19200
_Pt
Parità
0
No parity
1
Odd
2
Even
• TC / LIN input parameters
tP
PROBE
TYPE
Probe: Voltage + Current
36 0...60mV
37 0...60mV
38 12...60mV
39 12...60mV
with
40 0...20mA
dec. point
41 0...20mA
42 4...20mA
0.0/999.9
43 4...20mA
32.0/999.9
44
0...10V
0.0/999.9
45
0...10V
32.0/999.9
46
2...10V
0.0/999.9
47
2...10V
32.0/999.9
48
0...5V
0.0/999.9
49
0...5V
32.0/999.9
50
1...5V
-199.9/400.0
51
1...5V
-199.9/752.0
52
0...1V
44.0/999.9
53
0...1V
111.0/999.9
54 200mV...1V
-100.0/750.0
55 200mV...1V
-148.0/999.9
Probe: Custom PT100 - PTC - NTC
0.0/999.9
56
PT100
32.0/999.9
JPT
0.0/600.0
57
PTC
32.0/999.9
58
NTC
-199.9/400.0
-199.9/752.0
0.0/999.9
32.0/999.9
0.0/999.9
32.0/999.9
Max. non-linearity error for
0.0/999.9
thermocouples (TC),
32.0/999.9
resistors (PT100) and
Custom
Custom
thermistors (PTC, NTC)
-199.9/850.0
-199.9/999.9
The error is calculated as
-199.9/600.0
deviation from theoretical
-199.9/999.9
value and is expressed as
percentage of full scale (in
-55.0/120.0
-67.0/248.0
°C)
-10.0/70.0
14.0/158.0
• Sr
s. i
Virtual instrument inputs
Inputs
Bits
Ex.:
To manage PV and IN from serial line, the
code to be set in S.I is 48.
s. o
Virtual instrument outputs
Outputs OUTW
Bits
Ex.:
To manage OUT1, OUT2 and OUT3 from serial
line, the code to be set in S.0 is 19.
s. U
Interf.
KEYB
Bits
7
6
Ex.:
0
1
To manage KEYB and LED OUT1 from serial line, the code
to be set in S.U is 65
without
with
decimal point
decimal point
-1999/9999
-199.9/999.9
linear custom
linear custom
-1999/9999
-199.9/999.9
linear custom
linear custom
-1999/9999
-199.9/999.9
linear custom
linear custom
-1999/9999
-199.9/999.9
linear custom
linear custom
-1999/9999
-199.9/999.9
linear custom
linear custom
-1999/9999
-199.9/999.9
linear custom
linear custom
-1999/9999
-199.9/999.9
linear custom
linear custom
-1999/9999
-199.9/999.9
linear custom
linear custom
-1999/9999
-199.9/999.9
linear custom
linear custom
-1999/9999
-199.9/999.9
linear custom
linear custom
custom
custom
custom
custom
custom
custom
S, R range 0...1750°C; error < 0.2% f.s. (t > 300°C)
for other range; error < 0.5% f.s.
T
error < 0.2% f.s. (t > -150°C)
B
range 44...1800°C; error < 0.5% f.s. (t > 300°C)
range 44,0...999,9; error < 1% f.s. (t > 300°C)
U
range -99,9...99,9 e -99...99°C; error < 0.5% f.s.
for other range; errore < 0.2% f.s. (t > -150°C)
G
error < 0.2% f.s. (t > 300°C)
D
error < 0.2% f.s. (t > 200°C)
C
range 0...2300; error < 0.2% f.s.
for other range; error < 0.5% f.s.
NTC errore < 0.5% f.s.
Tc type J, K, E, N, L error < 0,2% f.s.
JPT100 e PTC
PT100 range -200...850°C accuracy at 25°C lower than
0,2% f.s.. In range 0...50°C:
• accuracy lower than 0,2% f.s. in range -200...400°C
• accuracy lower than 0,4% f.s. in range +400...850°C
(where f.s. is referred to range -200...850°C)
13
0 ... 63
IN
PV
AL4 AL3 AL2
5
4
3
2
1
1
0
0
0
0 ... 31
OUT4 OUT3
OUT2
4
3
2
1
1
0
0
1
User interface
0 ... 127
Virtual instrument
DISP LED
LED LED LED
OUT4 OUT3 OUT2 OUT1
5
4
3
2
1
0
0
0
0
0
In case of custom linearization, test
limits for setting LO and HI errors
are given by the calibration values.
If these limits are not exceeded,
they are taken into consideration as
limits L.S and H.S.
N.B.: for the version R77 are not
available the probe codes 0...39,
48...51, 54...58
error < 0,2% f.s.
AL1
1
0
0
OUT1
0
1
0
1