HOW TO RESET THE UNIT
The RESET button allows you to return all settings to its factory
values. The button is required only when the unit is not operating in
a favorable way, such as in the rare case of a malfunction.
The RESET button is located inside the battery compartment door.
To use the button,
1. Lift open the battery compartment door.
2. Press the button with a blunt stylus.
3. Replace the battery compartment door.
PRECAUTIONS
This unit is engineered to give you years of satisfactory service if
you handle it carefully. Here are a few precautions:
1. Do not immerse the unit in water. If you spill liquid over it, dry
it immediately with a soft, lint-free cloth.
2. Do not clean the unit with abrasive or corrosive materials. They
may scratch the plastic parts and corrode the electronic circuit.
3. Do not subject the unit to excessive force, shock, dust, tempera-
ture or humidity, which may result in malfunction, shorter
electronic life span, damaged battery and distorted parts.
4. Do not tamper with the unit's internal components. Doing so
will invalidate the warranty on the unit and may cause unnecessary
damage. The unit contains no user-serviceable parts.
5. Only use fresh batteries as specified in the user's instructions.
Do not mix new and old batteries as the old ones may leak.
6. Always read the user's instructions thoroughly before operating
the unit.
TIME ZONE AND OFFSET TABLE
SPECIFICATIONS
• Temperature Measurement
Main unit
Indoor Temperature measurement
Displayed IN temperature range : -50.0°C to +70.0°C
Proposed operating range
(-58.0°F to 158.0°F)
: -5.0°C to +50.0°C
(23.0°F to 122.0°F)
Temperature resolution
Remote Temperature measurement
Displayed OUT temperature range : -50.0°C to +70.0°C
Proposed operating range
Temperature resolution
Remote unit
Displayed range
Proposed operating range
Temperature resolution
RF Transmission Frequency
No. of Remote unit
RF Transmission Range
Temperature sensing cycle
• Relative Humidity Measurement
Indoor relative humidity measurement ranging from 25%RH to
95%RH
• Barometric Pressure Measurement
Pressure measuring range
Pressure sampling cycle
• Moon Phase Functions
Moon Phase Scanner Range
• Radio Controlled Clock
- Maintime set and synchronized by Radio Signal DCF77 for
Continental/ Central Europe
- user selectable 12 or 24h display with hh : mm ss
- Date Format : Day-Month-Year or Month-Day-Year
- Day of week selectable in 5 language (E, F, D, I, Sp )
- 2-minute crescendo alarm
• Power
Main unit
Remote sensing unit
• Weight
Main unit
Remote sensing unit
• Dimension
Main unit
Remote sensing unit
6
: 0.1°C (0.2°F)
(-58.0°F to 158.0°F)
: -5.0°C to +50.0°C
(23.0°F to 122.0°F)
: 0.1°C (0.2°F)
: -50.0°C to +70.0°C
(-58.0°F to 158.0°F)
: -20.0°C to +60.0°C
(-4.0°F to 140.0°F)
: 0.1°C (0.2°F)
: 433 MHz
: one
: Maximum 30 meters
: around 30 seconds
: 795 to 1050 mb/ hPa
(23.48 to 31.01 inHg)
: 15 minutes
: From 1990 to 2089
: use 4 pcs UM-3 or "AA"
1.5V alkaline batteries
: use 2 pcs UM-4 or "AAA"
1.5V alkaline batteries
: 306 gm
: 100 gm
: 182(L) x 133(W) x 28(T)
mm
: 92(L) x 60(W) x 21(T) mm

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido