Water Heating Temperature ("Set Point") - Jacuzzi UNIQUE Manual De Instalación

Ocultar thumbs Ver también para UNIQUE:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 77
Temperature adjustment LED
heater LED
fi ltering LED
Spotlight operation LED
blower operation LED
Pump operation LED
pump
blower
spotlight
viewing and adjusting temperature,
parameters, functions
Now insert the password 123 as follows:
- use the key "Up/Down"
NOTE: hold the key down until you reach the desired value. If the
display is equipped with two separate keys, press the key "Up" to
increase the value or the key "Down" to decrease it.
- confi rm the selection by pressing the key "Light"
Perform the same steps to insert the other two numbers.
Once you have inserted the password, the display will show the
message I1x (where "x" may be 1 or 0; the memorized value is 0).
Use the key "Up/Down"
responding to the scale in °F). Confi rm the selection with the
"Light"
key. The display will show the message I2x.
Press the "Light"
key again to go to parameter I3 0, which
must never be modifi ed.
Press the "Light"
key one more time to exit the procedure
and memorize the new values. The display will go off for a mo-
ment, and then it will come on again.
To go back to the Celsius scale (°C), return to the procedure and
set fi gure "x" of the parameter I1x to 0.
NOTE: If no key is pressed for 20 seconds, you will exit the procedu-
re and any changes made will not be saved.

Water heating temperature ("set point").

To check or modify the water heating temperature, do the following:
Press the key "Up/Down"
to select the fi rst numeral.
.
to change "x" from 0 a 1 (cor-
: the display will show the cur-
rently memorized temperature (in °C or °F as programmed; see
"Unit of measurement of the temperature").
Press the key "Up/Down"
lue from a minimum of 15 °C to a maximum of 40 °C (59÷104 °F).
NOTE: if you press the upper part of the key, the displayed value
increases. If you press the lower part, it decreases.
If the display is equipped with two separate keys, press the key
"Up" to increase the value or the key "Down" to decrease it.
To show the temperature of the water in the tub again, do
not touch any key for about 5 seconds.
As soon as the water temperature set point is reached, the
heater is shut off . It will not be turned back on until the water
temperature drops about 0.5 °C (1 °F) below the set point.
To ensure precise measurement of the water temperature,
the fi ltering pump comes on every half hour for about 30 se-
conds (even if no fi ltering cycles were set), since the temperature
probe is located in the heater pipe.
NOTES
When the system is turned off , or there is a power outage, the last
set point is stored in memory.
Operation of the heater is shown on the display by a LED on ste-
ady under the symbol
been suspended to keep from exceeding the maximum permitted
consumption. See also the previous note.
As a rule of thumb, an electric heater of approximately 2 kW in-
creases the temperature of 1 m
(with the thermal cover on the spa and without considering system
heat losses).
33
version without blower
again to change the displayed va-
. If it is fl ashing, it means that heating has
3
of water by roughly 1.7 °C per hour