FAILURE TO COMPLY WITH WHAT IS
PRESENTED BELOW MAY COMPROMISE
THE SAFETY OF THE EQUIPMENT.
THE MANUFACTURER WILL NOT BE
LIABLE FOR ANY DAMAGE OR INJURY
RESULTING FROM FAILURE TO
OBSERVING THE FOLLOWING RULES.
Identify the specific appliance model. The model
number is detailed on the packing and on the
appliance dataplate.
The appliance must be installed in a well-ventilated
room.
Installation and conversion to a different type of gas
must be carried out by qualified technicians
authorized by the manufacturer, in compliance with
current safety standards and the instructions in this
manual.
Appliance maintenance and conversion to a
different type of gas must be carried out by
qualified
technicians
manufacturer, in compliance with current safety
standards and the instructions in this manual.
Do not obstruct any air vents or drains present on
the appliance.
Do not tamper with appliance components.
4. REFERENCE STANDARDS AND LAWS
- Install the appliance in accordance with the safety
standards in force in the country.
5. UNPACKING
- Check the state of the packing and in the event of
damage, ask the delivery person to inspect the
goods.
- Remove the packing.
- Remove the protective film from the outer panels.
Use a suitable solvent to remove any residual
adhesive from the panels.
6. POSITIONING
The overall dimensions of the appliance and the
position of connections are given on the installation
diagram at the end of this manual.
The appliance can be installed singly or in
combination with other appliances in the same
product range.
authorized
by
the
The appliance is not suitable for integrated
installation.
Position the appliance at least 10 cm from adjacent
walls.
If the appliance is to be be placed near walls,
dividers, kitchen furniture, decorative elements etc.
this must be made of non-combustible materials
Otherwise, they must be covered with suitable
non-combustible heat insulating materials.
Level the appliance by means of the height-
adjustable feet
APPLIANCE ASSEMBLY WITH BASE AND BRIDGE
Follow the instructions provided with the type of
support utilized.
FUMES EXHAUST SYSTEM
Create a fumes exhaust system based on the " Type
" of appliance. The " Type " is stated on the
appliance dataplate.
" A1 " TYPE APPLIANCE
Position the "A1" type appliance below an extractor
hood to ensure smoke and fumes generated by
cooking are removed.
" B21 " TYPE APPLIANCE
Position the "B21" type appliance below an
extractor hood.
" B11 " TYPE APPLIANCE
Fit the "B11" type appliance with a suitable fl ue,
available from the appliance manufacturer. Follow
the assembly instructions provided with the flue.
Connect the flue to a 150/155 mm diameter hose,
heat resistant to 300°C.
Vent to the outside or into an effi cient fl ue. The
hose length must not exceed 3 metres.
7. CONNECTIONS
The position and dimensions of connections are
given in the installation diagram at the end of this
manual.
CONNECTION TO THE GAS SUPPLY
19