5.6 Storage Hints

If the unit is to be laid up or kept idle for any length
of time, proceed as follows:
a) Rinse and clean thoroughly. Never use formula
container of your mist blower for storing
chemicals.
b) Shut off fuel cock and keep engine running
until lines and carburetor are empty. Otherwise
gasoline evaporates, and the remaining
lubricant would clog the carburetor ducts.
c) Remove spark plug and squirt an ounce or two
of corrosion inhibitor (LPS, WD-40 etc.) or
plain engine oil into the cylinder. Crank engine
several times to spread the agent, and then
reinsert spark plug.
d) Please store your machine away from sunlight,
order to protect of the materials against
influence of ultraviolet radiations.
e) Before putting the unit back into service,
remove and clean spark plug; crank engine a
few times with plug removed.
For transport in a vehicle, ensure the
mistblower is well secured to avoid fuel
spillage.
Completely empty the fuel tank before extended
storage or shipment.

6. Fuel information

The engine of your motorized mistblower is a high
performance 2-cycle engine and has to be
operated with a fuel/oil mix or with a special, pre-
mixed fuel for 2-cycle engines available from
specialized dealers.
For the fuel mixture, use lead-free regular
(standard) petrol, lead-free Euro-petrol or lead-free
Super (premium) petrol. The minimum octane
rating is 92 ROZ.
Mixing Ratio:
We recommend a mixing ratio of 50 parts fuel to 1
part of oil (1:50 – 2%) with the use of special 2-
cycle oil "SOLO Profi 2T Oil". When using other -
cycle oils we recommend a mixture ratio of 1:25
(4%). Note: Never store fuel mixture for longer
than 3-4 weeks.
Solo Profi 2T
1:50 (2%)
3
1000 cm
(1Liter)
20 cm
3
5000 cm
(5 Liter)
100 cm
3
10000 cm
(10 Liter)
200 cm
All manuals and user guides at all-guides.com
Other brand
2-T-Oils
1:25 (4%)
3
3
40 cm
3
3
200 cm
3
3
400 cm
Maintenance and care; Fuel information
For the first 5 tank fillings, also when using
special -cycle oils, use a mixing ration of 1:25
(4%)!
x
Smoking or open flame is prohibited
x
Allow engine to cool before re-fuelling
x
Fuel may contain solvent-like substances.
Avoid skin and eye contact with mineral
products. Wear gloves while refueling.
Frequently change and clean protective
clothing. Do not inhale fuel vapors.
x
Do not spill fuel or oil. In case of spillage,
immediately wipe off mistblower. Do not allow
fuel mix to contact clothing. If fuel mix is spilled
on clothing, change clothing immediately.
x
Ensure fuel or oil do not contaminate soil
(environmental protection). Always use a
suitable protective soil cover.
x
Do not re-fuel in unventilated rooms. Fuel
vapors collect at ground level (danger of
explosion).
x
Transport and store fuel and oil only in
approved and clearly marked containers.
Children should have no access to fuel or oil.
x
Ensure you do not inhale exhaust fumes while
using the machine. The use of the motorized
mistblower is prohibited in closed rooms.
The handling of fuel requires caution
and consideration. It is imperative that
all safety instructions are observed!
Only refuel when the engine has been
stopped!
x
Clean the area around filler inlet before
refueling.
x
Remove tank lid and fill fuel mix up to the lower
edge of the filler neck. Do not overfill. If
possible, always use a fuel funnel with filter.
x
Fill in card fully to avoid spilling of fuel or oil.
x
Replace and secure fuel tank lid.
ENGLISH 7