must be such that when
viewing ompressor from
opposite shaft end, rotation
of shaft is clockwise as shown
by arrow on guard. Wrong
direction rotation for any
length of time will result in
damage to compressor.

Grounding Instructions

This product should be
connected to a grounded,
CFM
20
40
60
100
For Service and Warranty, Call: 1-888-303-1344
®
20, 25 & 30 HP
304CAS546-A
(Ref. Drawing)
Figure 1-1 Wiring Diagram
metallic, permanent wiring
Wiring
system, or an equipment
grounding terminal or lead on
the product.
Air Line Piping
Connection to air system should
be of the same size, or larger,
than discharge pipe out of unit.
The table gives recommended
minimum pipe sizes. A union
connection to the unit and water
drop leg is recommended.
Minimum Pipe Sizes For Compressor Air Lines
(Based on Clean Smooth Schedule 40 Pipe)
25'
3/4"
3/4"
1"
1"
1WD36, 1WD37, 1WD38, 1WD40, 1WD44
50'
100'
3/4"
3/4"
1"
1"
1"
1 ¼
1 ¼"
1 ¼"
6
Install a flexible connector between
the discharge of the unit and the plant
air piping. Plant air piping should be
periodically inspected for leaks
using a soap and water solution for
detection on all pipe joints. Air
leaks waste energy and are expensive.
Never use plastic
pipe or improperly rated metal
pipe. Improper piping materials
can burst and cause injury or
property damage.
200'
300'
1"
1"
1"
1"
1 ¼"
1 ¼"
1 ½"
1 ½"