Location
The tank must sit level or slope slightly towards the drain valve to allow the tank to drain properly. Check and
tighten all bolts, fittings, etc., before operating compressor.
It is extremely important to install the compressor in a clean, well ventilated area where the surrounding air
temperature will not be more than 100°F. A minimum clearance of 4 inches between the compressor and a wall is
required because objects could obstruct air flow.

Electrical Installation

voltage shown. Connect tool to a power line with the appropriate voltage and a 15-amp branch circuit.
Use a 15-amp time delay type fuse or circuit breaker. To reduce the risk of shock or fire, if power cord
is worn or cut, or damaged in any way, have it replaced immediately.
The A-C motor used on this compressor is a capacitor start,
capacitor run non-reversible induction type, having the
following specifications. It is wired at the factory for operation
on 110V-120V AC, 60 Hz service. In the event of a malfunction
or breakdown, grounding provides a path of least resistance
for electrical current to reduce the risk of electric shock.
This compressor is equipped with an electric cord having an
equipment-grounding conductor and a grounding plug, as
shown. The plug must be plugged into a matching outlet that
is properly installed and grounded in accordance with all local
codes and ordinances.
Improper connection of the equipment-grounding conductor can result in a risk of electric shock. The conductor
with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding
conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment-
grounding conductor to a live terminal.
electrical codes.

General Electrical Connections

1.
Use only identical replacement parts when servicing. Servicing should be performed by a
qualified technician.
2.
Do not use in rain or where floor is wet. This tool is intended for indoor residential use only.
110-120 Volt, 60Hz Information
The plug supplied on your compressor may not fit into the outlet you are planning to use. Your local electrical
code may require slightly different power cord plug connections. If these differences exist refer to and make the
proper adjustments per you local code before your compressor is plugged in and turned on.

Grounding Instructions

1. The air compressor should be located where it can be directly plugged into an outlet. An extension cord
should not be used with this unit.
2. To avoid loss of power and overheating, additional air hose must be used to reach work area instead of
extension cords.
3. Check with a qualified electrician or serviceman if grounding instructions are not completely understood, or if
in doubt as to whether product is properly grounded. Do not modify plug provided; if it will not fit outlet, have
proper outlet installed by a qualified electrician.
6
Do not locate the compressor air inlet near steam, paint spray, sandblast areas or
any other source of contamination.
To reduce the risk of electrical hazards, fire hazards or damage to the tool, use
proper circuit protection. Your tool is wired at the factory for operation using the
All wiring and electrical connections should be performed by a qualified
electrician. Installation must be in accordance with local codes and national
To reduce the risk of electrocution:
Do not permit fingers to touch the terminals of plug when installing or removing
the plug to or from the outlet.
If not properly grounded, this tool can cause an electrical shock, particularly
when used in damp locations, in proximity of plumbing, or out of doors.
Do not use a grounding adapter with this product!
Grounded
Outlet
Grounded
Pin
Figure 2