Safety Notes; Installation Instructions; Symbol Description; Technical Data - Hansgrohe Axor Starck 10030000 Modo De Empleo/Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The shower system may only be used for bathing,
hygienic and body cleansing purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

The fitting must be installed, flushed and tested after
the valid norms.
If the instantaneous water heater causes problems or
if you wish to increase the water flow, the EcoSmart
(flow limiter) located behind the aerator can be
removed.

Technical Data

This mixer series-produced with EcoSmart
limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Hansgrohe mixers can be used together with hydrauli-
cally and thermically controlled continuous flow heaters
if the flow pressure is at least 0,15 MPa.
4
English

Symbol description

®
(flow
®
max. 1 MPa
0,1 – 0,5 MPa
1,6 MPa
max. 80°C
65°C
Assembly see page 31
Do not use silicone containing acetic acid!
Dimensions (see page 33)
Flow diagram (see page 33)
with EcoSmart
®
without EcoSmart
®
Operation (see page 35)
Cleaning see enclosed brochure
Spare parts (see page 36)

Special accessories

special tool (58085000) order as an extra
Installation kit order as an extra
Test certificate (see page 35)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Starck 10050000Starck 10058000Starck 10230000

Tabla de contenido