8.2
Other Faults
Fault
not ON
Pressure too low
Machine is running with pul-
sating pressure and makes
knocking noise
No detergent drawn in
Burner soots up
20
Cause
>
Flashing light
- Motor is overheated
>
Flashing light
- Faulty temperature sen-
sor (B1)
>
Flashing light
- Flow sensor fault
>
Flashing light
- Overheat error has oc-
curred
>
Visual test of lamps
- When switching on,
all LEDs light up for
approximately 1 second
Cause
>
Plug not connected to the electri-
cal plug socket
>
High pressure nozzle worn out
>
Pressure regulation set to low
pressure or VarioPress-lance
set to low water volume
>
Pump has drawn in air as the
detergent tank is empty
>
Detergent tank empty
>
Dirt in detergent tank
>
Suction valve at cleaning agent
inlet soiled
>
fuel contamination
>
Burner sooted or adjustment
incorrect
Remedy
Turn main switch to position
"OFF" - let the machine cool
down
Remove/disconnect extension
cable
Possible phase failure on 3
phase variants
cal connection checked
Contact Nilfi sk-ALTO Service
>
Cold water operation is pos-
sible
>
Check wire to temperature
sensor (B1)
>
Contact Nilfi sk-ALTO Service
>
Cold water operation is pos-
sible
>
Contact Nilfi sk-ALTO Service
>
Cold water operation is pos-
sible
>
Contact Nilfi sk-ALTO Service
•
Put the plug into the electrical socket.
•
Check fuse (see chapter 9.4 Technical
Data)
•
Replace nozzle
•
Turn the twist grip on safety control
1)
block clockwise (+) or set VarioPress-
1)
.
lance
to higher water volume (see
1)
chapter 4.4)
•
Close detergent valve. Remove lance
from gun. Operate spray gun and let
machine run until air in pump is gone and
the machine is running normally again.
•
Top up detergent tank
•
Clean detergent tank
•
Remove suction valve and clean or
replace
•
Contact Nilfi sk-ALTO Service
: have electri-
1)
Remedy
Options / model variants
1)
Original instruction