Overview; Technical Data - oventrop Regtronic S-Bus Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Overview

"S-Bus interface adapter"
The "S-Bus interface adapter" is used for the speed con-
trol of a pump via a PWM or 0 - 10 V signal. Via the S-Bus
the adapter receives information from the controller about
speed. The speed is converted into a PWM or direct volt-
age signal and put out to the corresponding terminals.
A signal corresponding to the speed is only available if the
corresponding relay is designed for pump speed control.
Otherwise, a signal – depending on the position of the
relay – for the on or off state is transmitted.

Technical data

housing: plastic
Protection type: IP 20 (EN 60529)
Ambient temperature: 0 ... 70 °C
Dimensions: 95 × 70 × 25 mm
Mounting: Wall mounting is possible (but not required)
Display: 7-segment LED display
Power supply:
Mains adapter power supply: 100 ... 240 V~ / 50 ... 60 Hz
Interface adapter power supply: 12 V
5.5 × 2.1 mm
Interface: S-Bus
• Speed control of high-efficiency pumps for
controllers without integrated PWM outputs
• Easy to install
• convertible from PWM to 0-10 V signal
• With 7-segment LED display
Included:
1 × mains adapter 12 V
1 × S-Bus cable 1.5 m
1 × accessory bag containing
/ 1 A
/ 1 A / 5.5 x 2.1 mm
2 × screw and wall plug
4 × self-adhesive, skid-proof rubber pad
oventrop
Artikel-Nr. 1369531
Adapter S-Bus
PWM
Adapter S-Bus
0-10 V
Input: DC 12 V / 1 A
-
+
IP20
11 |

Publicidad

Tabla de contenido
loading

Tabla de contenido