Programming
1
Example - Individual programming sequence
Desired setting
Flow time: 15 s
Stagnation flush: On (ON)
1
G
Factory setting:
- Flow time - 8 s
- Stagnation flush off
1. Programming
Disconnect power supply (cf. Pg. 4),
reconnect after approx. 15 s, wait until
the LED shows a solid red light (appr.
15 s). Press 3 times within the red pha-
se -> program mode
Press 1 – 10 x -> flow time according
to table; Flow time begins at 4 seconds
2. Carry out flow time setting, if
required
Press x
1 2 3 4 5 6 7 8 9 10
number
Flow
4 6 8 10 15 25 30 45 60 120
time (s)
According to the flow time setting you
want:
LED flashes appr. 5 s after the last 2 ti-
mes pressed-> flow time programming
completed, then 5 sec time for setting
option for stagnation flush.
3. Stagnation flush
3.1 - stagnation flush ON:
Press 1x (LED flashes 4x)
3.2 - stagnation flush OFF:
Press 1x (LED flashes 2x)
4. LED flashes 5x -> programming