is not possible to deactivate the mode.
11.8
SLEEP FUNCTION (MAIN MENU)
The sleep function is activated only when the boiler is switched on and allows to quickly set a time at which
the product must switch off.
To set the Sleep function act as follows:
• Enter MENU
• Scroll to SLEEP with the <> arrows
• Press Menu
• With the + - keys adjust the desired shutdown time.
The panel proposes a shutdown time of 10 minutes from the current time, adjustable with key 4 until the
next day (I can therefore delay the shutdown for up to a maximum of 23 hours and 50 minutes).
If the SLEEP function is active with the TIMER active the first has priority over the latter, therefore the boiler will
not switch off at the time set on the timer but instead by the time established by the sleep function, even if
later than the time set on the timer.
11.9
AUXILIARY BOILER (SEE SECTION 8I)
One must install an additional module (optional) to enable start-up of an auxiliary boiler in the event the
stove is switched off or in alarm conditions. By default this function is deactivated, if needed activate it to
access the settings menu.
11.10
PELLETS RECIPE (SEE SECTION 8j)
This function is for adapting the stove to the pellets that are being used. In fact, as there are several types
of pellets on the market, boiler operation is extremely variable depending on the fuel quality. In the event
the pellets tend to clog the brazier due to an excessive load of fuel or in the event the flame is always high
even at low powers and, vice versa if the flame is low one can decrease/increase the amount of pellets
in the brazier:
The available values are:
-3 = Decrease by 30% compared to factory settings.
-2 = Decrease by 20% compared to factory settings.
-1 = Decrease by 10% compared to factory settings.
0 = No variation.
1 = Increase by 5% compared to factory settings.
2 = Increase by 10% compared to factory settings.
3 = Increase by 15% compared to factory settings.
11.11
SMOkE RPM VARIATION (SEE SECTION k)
If the installation presents difficulties for smoke evacuation (no draught or no pressure in the duct), the
smoke and ash expulsion speed can be increased. This change resolves all the potential problems related
to pellets clogging in the brazier and deposits forming at the bottom of the brazier itself caused by poor
quality fuel or fuel that produces a lot of ashes. The values available are from -30% to +50% with variations
of 10 percentage points at a time. The variation in negative can be used in case the flame is too low.
11.12
PUMP ON T (EXPERIENCED USERS ONLY) - SEE SECTION 8H
This menu item allows to adjust the pump activation temperature.
11.13
MAXIMUM POWER (EXPERIENCED USERS ONLY) - SEE SECTION 8L
It allows to set the maximum flame limit at which the boiler can operate to reach the set temperature
target.
CHIMNEy SWEEP FUNCTION (for maintenance technicians only) - see section 8n
This function can be activated only when the boiler is on and with power output and heating operation
power with parameters P5, with fan (if present) in V5. Any loading/smoke ventilation percentage corrections
must be taken into account. This status lasts 20 minutes, the countdown is displayed on the panel. During
AQUOS - IDRON