13.2
BEFORE EACH START-UP
Clean the ash and any deposits in the brazier that could clog the air passage holes.
If the pellets in the hopper finish, unburned pellets may accumulate in the brazier. Always empty the residue
in the brazier before startingup.
EN
For the brazier to be cleaned properly, remove it from its housing completely and thoroughly clean all the
holes and the grate on the bottom.
If good quality pellets are used, you will normally only need to use a brush to restore the optimal operating
conditions of the component.
13.3
CLEANING THE GLASS
It is recommended to clean the ceramic glass with a dry brush, or if it is very dirty, spray a little specific
detergent and clean with a cloth.
13.4
CLEAN THE EXCHANGER AND THE UNDERGRATE SPACE EVERY 2/3 DAYS.
Cleaning the exchanger and the undergrate space is a simple operation but very important for always
maintaining performance as declared.
Therefore we recommend cleaning the internal exchanger every 2-3 days, performing these simple
operations in sequence:
• Activate the "CLEANING" function – when the stove is switched of press - menu "3", select"Settings",
with the <> arrows "2-4" select "Cleaning", confirm with "Menu" "3", activate cleaning "ON" by pressing
the +- keys "5-6". This procedure activates the smoke extraction fan on maximum power to expel the
soot that is dislodged when the exchanger is cleaned.
• Clean the pipe unit – Using the hook provided, shake the rods located under the top (A to Fig. 28 a pag.
85) vigorously 5-6 times. This operation removes the soot that has deposited on the exchanger smoke
ducts during normal stove operation.
• Clean the smoke conveyor compartment - Stoves are fitted with a removable ash pan "C" designed to
collect any soot and ash build-up.
• Disable the "CLEANING" function - this function is automatically disabled after two minutes. If one needs
to stop this function in advance press the "Esc" key.
84
REMEMBER THAT ONLY A CORRECTLY POSITIONED AND CLEAN BRAZIER CAN GUARANTEE
START-UP AND OPTIMAL OPERATION OF YOUR PELLET PRODUCT.
ATTENTION!
Do not use abrasive products and do not spray the glass spray cleaner on the painted
parts or the door gaskets (ceramic fibre cord).
If these cleaning operations are not performed every 2-3 days, the stove could go into
alarm conditions due to ash clogging after several hours of operation.