Installation; Positioning - SCHOLTES B 40 L EC Serie Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Installation

! Before operating your new appliance please read this
instruction booklet carefully. It contains important
information concerning the safe operation, installation
and maintenance of the appliance.
! Please keep these operating instructions for future
reference. This manual contains important information
relating to appliance installation, operation and safety.

Positioning

! Keep packaging material out of the reach of children.
It can become a choking or suffocation hazard. (see
Precautions and tips).
! The appliance must be installed by a qualified
professional in compliance with the instructions
provided. Incorrect installation may cause harm to
people and animals or may damage property.
! This unit may be installed and used only in permanently
ventilated rooms in accordance with British Standard
Codes Of Practice: B.S. 6172 / B.S. 5440, Par. 2 and B.S.
6891 Current Editions. The following requirements must be
observed:
The following requirements must be observed:
• The room must be fitted with an air extraction
system which expels any combustion fumes. This may
consist of a cooker hood or an electric fan which starts
automatically every time the appliance is switched on.
• The room must also allow
proper air circulation, as air is
needed for combustion to occur
normally. The air flow must not
be less than 2 m
installed power.
The air circulation system may
take air directly from the outside
environment by means of a pipe
with an inner cross section of at
least 100 cm
not be vulnerable to any type of
blockages.
The system can also provide
the air needed for combustion
indirectly, i.e. from adjacent
rooms fitted with air circulation ducting as described
above. However, these rooms must not be communal
rooms, bedrooms or rooms which may present a fire
hazard.
• Liquid petroleum gas sinks to the floor as it is
heavier than air. Therefore, rooms containing LPG
cylinders must also be equipped with vents to allow gas
to escape in the event of a leak. As a result LPG
cylinders, whether partially or completely full, must not
be installed or stored in rooms or storage areas which
are below ground level (cellars, etc.). It is advisable to
keep only the cylinder currently being used in the room,
positioned so that it is not subject to heat produced by
external sources (ovens, fireplaces, stoves, etc. )
which could raise the temperature of the cylinder above
50°C.
Built-in appliance
Gas and mixed hobs are manufactured with type X
degree protection against overheating. The following
precautions must be taken when installing the hob:
• Kitchen cabinets which are adjacent to the appliance
and taller than the top of the hob must be at least 140
are adjacent to the cooker hood at a minimum height of
540 mm from the hob (see figure).
If the hob is installed beneath a wall cabinet, the latter
must be situated at a minimum of 700 mm above the
hob.
Installation
Installation
Installation
Installation
Installation
Make sure you take all the necessary precautions to
/h per kW of
3
guarantee proper installation in compliance with the
applicable norms in force regarding accident-prevention for
electrical connection. For the correct operation of the
appliance when built into the cabinet, it is vital that the
minimum distances illustrated in Fig. 1 be respected. The
hob features a type Y degree of protection against
; the opening must
2
overheating in compliance with norms. All surfaces
adjacent to the cabinet and the back panel should be
made of materials resistant to a temperature of 65°C.
mm from the edge of the hob.
• Cooker hoods must be
installed in accordance with
their relative installation
600mm min.
instruction manuals and at a
minimum distance of 700 mm
from the hob.
• Place wall cabinets which
GB
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

B 40 l ec 1 sfB 40 l ec f

Tabla de contenido