Technical Data

EN
General
Range
Measuring accuracy*
Smallest unit displayed
Laser class
Laser type
Autom. power switch-off
Continuous measuring
Area / Volume
Dimension (H x D x W)
Battery durability (2 x AAA) up to 3000 measure-
Weight
(without batteries)
Temperature range:
- Storage
- Operation
* The typical measurement uncertainty of ± 3 mm is
valid for measurements on white, diffusive, reflective
targets up to 5 m at low ambient light and moderate
temperatures. For distances greater than 5 m, the
measurement uncertainty could increase additionally
by 0.1 mm/m. In unfavourable conditions (such as
bright sunlight, targets with poor reflectivity, or high or
low temperatures) the measurement uncertainty
could further increase up to ± 4 mm for distances
below 5 m and additionally by roughly 0.15 mm/m for
distances greater than 5 m.
6

Message Codes

If the message Error does not disappear
after switching on the device repeatedly,
21 cm - 20 m
contact the dealer.
8'' - 65'
If the message InFo appears with a
± 3 mm
number, press the Clear button and
± 1/8''
observe the following instructions:
1 mm
No.
Cause
1/16 in
252
Temperature too high Let device cool
2
635 nm, < 1 mW
253
Temperature too low
after 120 s
255
Received signal too
yes
weak, measuring time
yes
too long
110 x 44 x 21 mm
256
Received signal too
4.33 x 1.73 x 0.83 in
high
ments
257
Too much background
light
71 g / 2.5 oz
258
Measurement outside
of measuring range
-25 to 70 °C
260
Laser beam inter-
-13 to 158 °F
rupted
0 to 40 °C
32 to 104 °F
Correction
down.
Warm device up.
Change target
surface (e.g. white
paper).
Change target
surface (e.g. white
paper).
Shadow target area.
Correct range.
Repeat measure-
ment.
STANLEY TLM65

Care

• Clean the device with a damp, soft cloth.
• Never immerse the device in water.
• Never use aggressive cleaning agents
or solvents.

Disposal

CAUTION
Flat batteries must not be disposed of with
household waste. Care for the environ-
ment and take them to the collection points
provided in accordance with national or
local regulations.
The product must not be disposed with
household waste.
Dispose of the product appropri-
ately in accordance with the
national regulations in force in your
country.
Adhere to the national and country specific
regulations.
Product specific treatment and waste
management can be downloaded from our
homepage.

Warranty