Technical Characteristics - Gastrodomus Minitemper Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

piegh minitemper 12_2016.qxp_piegh minitemper 15/12/16 08:19 Pagina 14
CAUTION: "ALO" on the display
Whenever the probe (10) is tampered with and/or faulty and so can no longer detect the exact temperature, the
machine detects this and emits a continuous warning sound. At the same time the word "ALO" appears on the
display. You must switch the machine off (the buzzer stops) and replace the probe.
The PAVONI-ITALIA customer service is on hand at all times to provide any information or intervention you may require.
Hot-line: +39.035.4934111

TECHNICAL CHARACTERISTICS

- Voltage rating: 230/240 Volt / 50 Hz (upon request: 110 Volt / 60 Hz)
- Electrical input: 300 Watt
- Machine dimensions: 420 x 400 mm 400 mm h
- Total machine weight: 16 kg
- Packaging: dimensions: 520 x 500 mm 500 mm h
MAINTENANCE
The basic body of the machine is virtually maintenance-free: just keep all the external parts clean.
The basin and dividing wall should be cleaned regularly: wash with hot water, especially after each product change
and/or basin change
Trouble-shooting:
PROBLEM
T
'
HE MACHINE DOESN
T SWITCH ON
T
'
HE GLAZING DOESN
T MIX
T
HE GLAZING MIXES TOO SLOWLY
T
'
HE GLAZING DOESN
T COLL DOWN
(
)
HARDENING
T
'
HE GLAZING DOESN
T TURN
"ALO"
APPEARS ON THE DISPLAY
14
weight of machine+packaging: 20 kg
The cable isn't connected to the machine
or isn't connected correctly
The fuse has blown
Short-circuit or fuse blown
Not heated
Temperature control set too low
Temperature control set too low
Lamps defective
Level of glazing too low compared to
depth of bowl
Bowl doesn't turn
Fan not working
Temperature control set too high
Level of glazing too low compared to
depth of bowl
Room temperature too high
No electricity
Motor defective
Glazing not mixed
Probe not working properly
CAUSE
Plug the cable in correctly
Change the fuse
Replace or mend circuit
Replace lamps
Adjust temperature
Adjust temperature
Replace lamps
Add more glazing
Check motor
Replace fan
Adjust temperature
Add more glazing
Cool room to below 24°
Plug in
Change any blown fuses
Check motor
Remove and mix glazing (solidified on
scraper)
Check efficiency
Replace
REMEDY