Example 3: floor system + fan coil (FCU)
Note: The thermostat must be chosen according to the specifications given in the manual. The bypass valve must be installed on the manifold so as to
ensure sufficient water flow.
Example 4: heating and cooling system + domestic hot water (DHW) + auxiliary thermal source + integrative thermal source (KRIT)
Note: The 3-way valve must be installed in accordance with the specifications in the manual. The domestic hot water system (DHW) must be fitted with
an internal electrical resistance so as to ensure sufficient thermal energy on very cold days. The 2-way valve is very important to prevent condensation
phenomena during the cooling phase.
RT7
Domestic hot water probe
RT5
Additional source of heat / electrical resistance probe
V2V
2-way valve
ECH
Plate evaporator
VE1
Expansion tank on the machine
VE2
Auxiliary source of heat expansion tank
FL
Flow switch
VSA
Air vent valve
P
Electronic circulator
PU
Circulation pump
FA
Water side Y-filter
VS
Safety valve
KVDEV
ON-OFF 3-way valve + actuator KIT
V2V
ON-OFF 2-way valve
VM3
3-way mixer valve with delivery control
KRIT
Integrated source of heat (Electrical resistance)
RE
Evaporator anti-freeze resistance
REA
Sanitary water tank electrical resistance
FTA
Auxiliary thermal source
D
Disconnector
VT
Calibration valve
TA
Puffer
VR
Check Valve
T
Inertial tank positioned on the return section
TA
Heated towel rail
FCU
Fancoil
PR
Radiant panels