Installation - Jacuzzi frame in2 150x110 Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 51
PLEASE READ THESE INSTRUCTIONS THOROUGH-
LY BEFORE PROCEEDING WITH INSTALLATION
Before starting...
Check to ensure that the drain is operative, as well as connec-
tion to the water and electrical supply in the case of electronic
models.
During installation, the mixer system must be connected to the wa-
ter supply via two pipes capable of accommodating high flow rates
(internal Ø 10 mm) 1/2" M-F, 100 cm in length.
In the instance where you wish to connect the shower enclo-
sure to an alarm circuit, you must also use a bipolar cable (see
Chapter "Alarm Connection (where necessary)").
Before every installation phase, remove any bar code labels
present on shower enclosure components.
In order to ensure correct operation of the shower enclosure,
you should ensure even pressure and adequate water flow
(see the pre-installation technical specifications), in addition
to pipes with adequate cross-sections .
ATTENTION: (IEC 60335-1/A2) The pressure of the wa-
ter system supplying water to the appliance must not
exceed 600 kPa (6 bar).
ATTENTION: when moving glass panels, ONLY use suc-
tion lifters, suited to hold the weight of the glass pan-
els. Also use suitable protective gloves.
Installing the shower tray
Ensure the walls are perpendicular to the tray; wall mounted com-
pensators allow for a 10 mm error margin: errors of larger dimen-
sions can be rectified using suitable spacers or by removing the tray
from the wall.
MAX 10mm
90°
(
structures to the tray.
(
(
drainage pipe (A), carefully gluing the meeting points. Connect
the drainage pipe (B).
(
Check the spirit level of the tray (widening the rims where nec-
essary) and fix it to the floor using filler or equivalent materials;
place silicone between the tray and walls.
Do not place filler or silicone in the glass-profile area.
Installing the compensators
(
the perpendicularity and the distance with regards to the upper
tray rim.
Attach the compensator to the wall.
tach it to the compensator; place some silicone between the
frame and the tray, as indicated.
Installation of cladding profiles
(
profiles to the compensators. Fix the corner joint to the tray. Caulk.
(
perpendicularity.
Fix the brackets to the wall. Check the perpendicularity.
90°
Installation of trinket receptacle panel and clad-
ding panel
MAX 10mm
(
insert it inside the cladding profile.
7
7
1) Remove the protective film and fix the glass panel
2) Attach the screws to the front of the tray.
3) Connect the drainage column to the already prepared
During this phase, check that are no leakages from
the drain, as it will be too late once assembly is com-
plete. For example, place the tray on the supports and
pour water over, checking the seals of the connections
made.
We recommend levelling the area under the tray with
high-resistance cement mortar (or equivalent materi-
als) in order to secure an even support surface.
In the instance of recess or corner installation, a mini-
mum distance must be respected between the tray and
wall.
4) Completing installation of the drain.
ATTENTION: during installation, we recommend pro-
tecting the tray from any possible knocks or scratches.
5-5b) Place the compensator resting on the tray; check
6) Attach the bracket and corner joint. Insert the cladding
ATTENTION: the cladding profiles must be positioned
resting against the glass panel structures of the tray.
7) Fix the cladding profiles to the compensators. Check the
8-9) Fix the bracket. Apply the gasket. Raise the panel and

Publicidad

Tabla de contenido
loading

Tabla de contenido