Extension Cords; Functional Description; Carton Contents - Delta 31-695 Manual De Instrucciones

Lijadora de correa de 6 pulg./ disco de 9 pulg.
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EXTENSION CORDS

Use proper extension cords. Make
sure your extension cord is in good condition and
is a 3-wire extension cord which has a 3-prong
grounding type plug and matching receptacle which
will accept the machine's plug. When using an
extension cord, be sure to use one heavy enough to
carry the current of the machine. An undersized cord
will cause a drop in line voltage, resulting in loss of
power and overheating. Fig. C, shows the correct
gauge to use depending on the cord length. If in
doubt, use the next heavier gauge. The smaller the
gauge number, the heavier the cord.
FOREWORD
The Delta 31-695 features a large 9" diameter abrasive disc that is perfect for sanding large curves or rounding out
sharp corners. The Delta 31-695 also features an adjustable 6" belt unit that can be operated vertically or horizontally
or at any angle in between.
1
9
Fig. 1A
1. Sander with 6" x 48" Sanding Belt
2. Sanding Disc Plate
3. Belt and Pulley Cover
4. 9" Sanding Disc
5. T-Wrench
6. Backstop
7. Disc Cover
8. Support Rod
All manuals and user guides at all-guides.com

FUNCTIONAL DESCRIPTION

CARTON CONTENTS

2
7
8
7 - English
MINIMUM GAUGE EXTENSION CORD
RECOMMENDED SIZES FOR USE WITH STATIONARY ELECTRIC MACHINES
Ampere
Rating
Volts
0-6
120
0-6
120
0-6
120
0-6
120
6-10
120
6-10
120
6-10
120
6-10
120
10-12
120
10-12
120
10-12
120
10-12
120
12-16
120
12-16
120
12-16
120
3
4
6
5
9. Table Assembly
10. M6 x 12mm Socket Head Cap Screws (2)
11. M6 Flat Washer (4)
12. M6 Lock Washer (4)
13. M4.2 x 12mm Pan Head Tap Screw (3)
14. M6 x 55mm Socket Head Cap Screws (2)
15. M10 x 12mm Hex Set Screw (4)
Total
Length of
Cord in
Gauge of Extension
Feet
Cord
up to 25
18 AWG
25-50
16 AWG
50-100
16 AWG
100-150
14 AWG
up to 25
18 AWG
25-50
16 AWG
50-100
14 AWG
100-150
12 AWG
up to 25
16 AWG
25-50
16 AWG
50-100
14 AWG
100-150
12 AWG
up to 25
14 AWG
25-50
12 AWG
GREATER THAN 50 FEET NOT RECOMMENDED
Fig. C
10
11
14
12
15
13
Fig. 1B

Publicidad

Tabla de contenido
loading

Tabla de contenido