6-6
Press Menu/OK button. Setting
confi rmation screen is displayed.
6-7
Select
Yes
and press Menu/OK
button. Setting details are
determined and fi eld settings
screen returns.
6-8
In the case of multiple setting
6-3
changes, repeat "
6-9
After all setting changes are com-
pleted, press Cancel button
twice.
6-10
Backlight goes out, and
[Checking the connection.
Please stand by.] is displayed
for initialization. After the
initialization, the basic screen
returns.
NOTE
● Installation of optional accessories on the indoor unit may require changes to fi eld settings.
See the manual of the optional accessory.
●
For fi eld setting details related to the indoor unit, see installation manual shipped with the
indoor unit.
Mode
First
No.
Code
Description
(Note 1)
No.
Priority of thermistor
2
sensors for space
temperature control
10 (20)
Room temperature
5
value reported to
multizone controllers
Thermo-on/off
12 (22)
2
deadband
(Note 4)
Thermistor sensor for
auto changeover and
1
setback control by the
1c
remote controller
Access permission
3
level setting
1e
2
Setback availability
14
All manuals and user guides at all-guides.com
6-7
" to "
".
01
The return air
thermistor is
primary and the
remote
controller
thermistor is
secondary.
Return air
thermistor
2F (1C)
Utilize the return
air thermistor
Level 2
N/A
<Setting confi rmation screen>
6-
6
Field Settings
6-
7
Save the settings?
Yes
No
Setting
Press Menu/OK button.
Setting confi rmation
Second Code No. (Note 2)
(Items in bold are factory default settings)
02
The remote
controller
thermistor is not
utilized. Only
the return air
thermistor will
thermistor will
be utilized.
be utilized.
Thermistor
designated by
10-2 above
(Note 3)
1F (0.5C)
Utilize the remote
controller
thermistor
Level 3
Heat only
03
04
Only the
remote
controller
————
————
————
————
————
————
————
————
————
Cool only
Cool/Heat
English