Mounting; Electrical Installation - SICK WLA26 Serie Instrucciones De Uso

Ocultar thumbs Ver también para WLA26 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
4

MOUNTING

4
Mounting
en
5

Electrical installation

22
O P E R A T I N G I N S T R U C T I O N S | WLA26
WLA26x-xxxxxx30
1
6
3
2
BluePilot blue: alignment aid
1
LED yellow: status of received light beam
2
LED green: supply voltage active
3
Press-turn element: time function adjustment
4
Teach pushbutton: adjustment of light/dark switching
5
Teach-Button: adjusting the sensitivity
6
Mount the sensor and the reflector using suitable mounting brackets (see the SICK
range of accessories). Align the sensor and reflector with each other.
Note the sensor's maximum permissible tightening torque of < 1,3 Nm.
The sensors must be connected in a voltage-free state. The following information must
be observed, depending on the connection type:
Male connector connection: Note pin assignment
Cable: wire color
Only supply/switch on the voltage once all electrical connections have been estab‐
lished.
Explanations of the connection diagram (following tables):
Alarm = alarm output
Health = alarm output
MF (pin 2 configuration) = external input, teach-in, switching signal
Q
/C = switching output, IO-Link communication
L1
Test = test input
U
: 10 ... 30 V DC
B
Table 8: Connections
Wxx26x-
x4
1 = BN
2
2 = WH
3 = BU
4 = BK
3
5= GY
WLA26x-xxxxxx31
5
1
6
3
2
xH
1
2
0.14 mm
2
AWG26
4
3
WLA26x-xxxxxx32
4
1
6
3
2
x5
xI
1
5
4
0.14 mm
2
AWG26
8020357.1DS8/2021-11-24 | SICK