Sensing Range Setting - SICK WLA26 Serie Instrucciones De Uso

Ocultar thumbs Ver también para WLA26 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 35
7
COMMISSIONING
en
7.3

Sensing range setting

28
O P E R A T I N G I N S T R U C T I O N S | WLA26
Function reserve
1,000
WLA26P-xxxxx1xx
100
10
5
2
3
1
4
1
0
4
8
12
(13.12)
(26.25)
(39.37)
Figure 22: Characteristic line 4: Chemical-
resistant reflector
Reflector PL10F CHEM
1
Reflector P250H
2
Reflector P250 CHEM
3
Reflector PL20 CHEM
4
Reflector PL40A Antifog
5
WLA26x-xxxxxx3xAxx with teach-in button:
There must not be any objects located between the WLA26 and the reflector. The sensi‐
tivity is reduced by pressing the teach-in button (approx. 1-3 seconds). This primarily
suppresses false switching to extremely depolarizing objects. The sensing range is also
reduced, and therefore the operating reserve as well. Lead an object into the path of
the beam. The yellow display LED goes out, meaning the object is detected and the
setting is correct.
1
0.2
2
2
0
3
0
4
0
5
0
0
0
(6.56)
Sensing range
Figure 23: Bar graph 4: Chemical-resistant
Sensing range
Reflector PL10F CHEM
1
Reflector P250H
2
16
20
Reflector P250 CHEM
3
(52.49)
(65.62)
Distance in m (feet)
Reflector PL20 CHEM
4
Reflector PL40A Antifog
5
3
7
10
6
8
3.5
5
11
2
4
6
8
10
12
(13.12)
(19.69)
(26.25)
(32.81)
(39.37)
Distance in m (feet)
Sensing range typ. max.
reflector
8020357.1DS8/2021-11-24 | SICK
Subject to change without notice
14
14
(45.93)

Publicidad

Tabla de contenido
loading

Tabla de contenido