How to connect wiring to the terminal

■ For stranded wiring

(1) Cut the wire end with cutting pliers, then strip the insulation
to expose the stranded wiring about 10 mm and tightly
twist the wire ends.
Stranded wire
Ring
pressure
terminal
(2) Using a Phillips head screwdriver, remove the terminal
screw(s) on the terminal board.
(3) Using a ring connector fastener or pliers, securely clamp
each stripped wire end with a ring pressure terminal.
(4) Place the ring pressure terminal, and replace and tighten
the removed terminal screw using a screwdriver.
Special
Screw
washer
Ring pressure
terminal
Terminal board
Wire
All manuals and user guides at all-guides.com
Screw and
Special washer
Ring
pressure
terminal
Wire

■ Examples of shield wires

(1) Remove cable coat not to scratch braided shield.
(2) Unbraid the braided shield carefully and twist the
unbraided shield wires tightly together. Insulate the shield
wires by covering them with an insulation tube or wrapping
insulation tape around them.
(3) Remove coat of signal wire.
Insulation tape
(4) Attach ring pressure terminals to the signal wires and the
shield wires insulated in Step (2).