LED WORKLIGHT (FIG 17, 18, 19)
NOTE: The LED worklight and battery is supplied and fitted as a single component and cannot be serviced. If the LED or
battery needs to be replaced, a new unit should be fitted.
DO NOT dispose of this unit with household waste.
Always dispose of batteries according to local legislation.
Please recycle in line with local provisions for the collection and disposal of electrical and electronic
waste.
This component is excluded from any extended warranty and will operate for approx. 100,000 tool cycles.
OPERATION
To operate the LED work-light you must first remove an electricity isolated plastic sheet before using the LED work-light.
1. Pull up the nose cover to open.
2. Pull out the electricity isolated plastic sheet.
3. Close the nose cover.
4. LED light is on/off by pressing light button on the cover.
REMOVING THE LIGHT (Fig 20, 21, 22)
The LED work-light can be easily removed or if needed.
1. Pull up the nose cover to open
2. Press on the snap-fitting hook to release LED work-light.
3. Take out the LED work-light from the cover.
REPLACING THE LIGHT (N62-LED) (Fig 23, 24, 25)
Insert a new LED work-light.
1. Align housing of the LED work-light into nose cover until it snaps into position. Make sure the button is placed through
nose cover hole.
2. Pull out the elecricity isolated plastic sheet.
3. Close the nose cover.
INTEGRATED PENCIL SHARPENER (FIG 26,27)
A pencil sharpener is integrated into the magazine for the operator's convenience. To sharpen a pencil, insert any standard
pencil into the hole and rotate the pencil to the right (clockwise) to sharpen. Check compatability before use.
JAM CLEARANCE (FIG 28-33)
Warning! Always disconnect the air before clearing a jammed fastener.
Jam Clearing
1. Disconnect the tool from the air supply. (Fig 28)
2. Release the pusher so it is no longer applying force to the nail sticks. (Fig 29)
3. Open the jam clearing nose door by pulling down and then up on the latch. (Fig 30)
4. Remove the jammed fastener. In certain circumstances, pliers may be required to remove the fastener. (Fig 31)
5. Close the jam clearing nose door latch. (Fig 32)
6. Pull nail pusher back behind nail sticks. (Fig 33)