Operating Elements; Display Values - Siemens UH50 Manual Del Usuario

Ocultar thumbs Ver también para UH50:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 70
Only fit one compartment for the power supply. Do not
remove the red locking hatch.
3.
Operating
3.1

Operating elements

8
7
Number
Description
1; 6; 7; 8
Cover lugs
2
Button 1
3
Button 2
4
LCD
5
Security seal
Symbol
Description
Identification: Previous year's value (set day value)
Identification: Previous month's value
Symbol for heat meter
Symbol for cold meter
Installation site: Return-flow
Installation site: Flow
Year of manufacture
Note: Both display range and data displayed can differ
from the description depending on the appliance pa-
rameterisation. Certain button functions can also be
blocked.
3.2
Displaying current meter status
The meter displays the current meter status in kWh, MWh, MJ
or GJ.
Note: In order to prevent reading errors, the decimal
places of the values displayed are marked with a
frame.
Note: Calibrated values can be recognised by an
additionally displayed star symbol.

Display values

Switch to the service loops to display the values. Proceed as
follows:
To switch from the user loop into the service loops press
button 1.
The displays of the meter are arranged in several levels
(LOOPs).
To switch the LCDs between the loops press button 1.
The LCD shows the following values one after the other:
Service loop 1
Service loop 2
...
...
User loop
Siemens Building Technologies
After the last loop is displayed, the user loop "LOOP 0" comes
up again.
Switching in a loop
Proceed as follows to switch to the next display value within a
loop:
Press button 2.
The first display value will appear again after the final display
1
value.
User loop "LOOP 0"
2
The meter is located in the user loop "LOOP 0".
To switch to the next display value press button 2.
3
The LCD displays the following values one after the other:
4
5
6
Service loop 1 "LOOP 1"
Service loop 1 displays the details of the current measurement.
The LCD shows the following values one after the other:
Service loop 2 "LOOP 2"
Service loop 2 displays the measurement period for establish-
ing the maximum.
The LCD shows the following values one after the other:
Service loop 3 "LOOP 3"
Service loop 3 displays the monthly values.
In order to display the monthly values, press button 2.
The set day of the current month is displayed.
To select the desired month, press button 1.
...
To request the associated values, press button 2.
The LCD displays the following values one after the other:
CE2B5324xx
Energy accumulated with tariff status
Tariff register 1 (optional)
Volume accumulated
Segment test
Head of the loop
In case of error: message with error code
Head of the loop
Current flow
Current power
TV current temperature hot side,
TR current temperature cold side;
in 2-sec. cycles
Operating time
Operating time with flow
Missing time
Property number, 8-stellig
Date
Yearly set day (DD.MM)
Energy: previous year on set day
Volume: previous year on set day
Firmware version
Head of the loop
Measurement period for establishing the maximum
Head of the loop
...
Set day for July 2011
Energy on the set day
Tariff register 1 on the set day
Volume on the set day
08.08.2017
9