INSTALLATION
General connections
(ST1)
(ST2)
A.T (ST1) Total opening key command
A.P (ST2) Pedestrian opening key command
SG.C
Closing safety device (mechanical strip
or photocell)
AUX
Output (24Vac, 300mA)
Constant output in order to feed
peripheral devices
STOP
Emergency pushbutton
DEST
Flashing light (125/230Vac, max. 60W)
Connection of safety transmitter-receiver photocells in closing (SG.C)
52
Installation Manual
All manuals and user guides at all-guides.com
(ST1, start)
(ST2, pedestrian)
FC1
(DIP9=OFF: FCC)
(DIP9=ON: FCA)
ST1
COM
ST2
We recommend installing safety photocells.
1 Complete the connections as shown in the figure.
O If neither photocells nor a mechanical strip are connected,
make an electrical bridge between cable connectors (2) and (4).
FC2
(DIP9=OFF: FCA
(DIP9=ON: FCC)
A1
Operator motor
SMF
Traffic light card AEPS1-001
FCC
Magnetic closing limit switch (Hall effect
sensor)
FCA
Magnetic opening limit switch (Hall
effect sensor)
SW1
Main switch
ANT
Cable connectors for antenna
R.E
Plug-in receiver
(close)
(open)
P145X